4-4 ADS
Manual
Qstart
XML
Settings
dialog
Complete the
Settings
dialog in the following way:
1.
Enter the path or browse to the directory to which you want to
save location information files (XMLs) and collected flow data
in the
Data Path
field.
2.
Select the port on your computer through which you will
connect directly to the monitor from the
Serial Port
drop-
down list.
3.
Select the port on your computer through which you will
perform
Bluetooth
communications from the drop-down list
(
not applicable to monitors
).
4.
Select the units of measure (US or Metric) you want to use
throughout
Q
start
XML
when entering values, saving data, and
displaying data from the
Units
drop-down list. The
US
units
report quantity in MGD, depth in inches, and velocity in feet
per second. The
Metric
units report quantity in liters per
second, depth in millimeters, and velocity in meters per
second.
5.
Select the format in which you want to save data
collected
from the monitor from the
Data Format
drop-down list.
ADS
represents the ADS proprietary
Bin
format;
CSV
(comma-
separated value) represents a format generally compatible with
most spreadsheet applications, such as
Microsoft
®
Excel
®
.
Select
Both
to collect both the
ADS
and
CSV
file formats.
6.
Select the
Always use monitor XML as preferred
configuration
checkbox to ensure
Q
start
XML
automatically
overwrites the local configuration with the XML stored in the
monitor memory when an
Upload
is performed. Choosing this
option also automatically updates the local serial number with
the serial in the monitor (when an inconsistency exists between
the monitor and computer) whenever communication is
established with a monitor.
7.
Select the
Use ADS Dates for CSV
checkbox to store
collected
data in CSV files using the ADS date format. When
this option is
not
selected,
Q
start
XML
stores the CSV data in the
local
Windows
-configured regional date format.
Summary of Contents for 507165
Page 20: ...1 12 ADS TRITON Manual Control Drawing ...
Page 27: ...Introduction 1 19 CS6 LRD Sensor Certificate of Conformity ...
Page 29: ...Introduction 1 21 CSA Certificate of Compliance Page 1 of 7 ...
Page 30: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 2 of 7 ...
Page 31: ...Introduction 1 23 CSA Certificate of Compliance Page 3 of 7 ...
Page 32: ...1 24 ADS TRITON Manual CSA Certificate of Compliance Page 4 of 7 ...
Page 33: ...Introduction 1 25 CSA Certificate of Compliance Page 5 of 7 ...
Page 34: ...1 26 ADS TRITON Manual CSA Certificate of Compliance Page 6 of 7 ...
Page 35: ...Introduction 1 27 CSA Certificate of Compliance Page 7 of 7 ...
Page 37: ...Introduction 1 29 Sample TRITON Declaration of Conformity Page 2 ...
Page 53: ...System Overview 2 13 ExPAC XBUS ...
Page 266: ...5 60 ADS TRITON Manual z Installing the Submersion Sensor z Measuring the physical offset ...
Page 288: ...5 82 ADS TRITON Manual Topside Wall Mount Bracket Topside Sensor Bracket ...
Page 345: ...7 2 ADS TRITON Manual use of this installation guide or the installation of any ADS equipment ...
Page 358: ...Inclinometer 8 3 ...
Page 507: ...C 4 ADS TRITON Manual ...
Page 535: ...Index In 19 wiring to the monitor 6 29 XIO device parameters 4 84 ...