Reconnect the sensor cable(s) to the appropriate port(s)
(
Channel 1
and/or
Channel 2
) on the monitor.
Inspecting, Cleaning, and Handling the
Sensors
Perform the following sensor inspections during regular site visits:
z
Verify that the installation ring, bands or Mounting Bar are
secure and clear of debris.
z
Carefully remove any debris that has accumulated on or around
the Long Range Depth Sensor.
z
Clean the face of the Submersion Sensor with a clean, moist
cloth as needed.
z
Clean the face of the Surface Combo Sensor/Ultrasonic Depth
Sensor gently with a soft brush, and wipe the sensor with a
clean, moist cloth.
Note:
The crystals on the Surface Combo Sensor are
covered with a Teflon
®
coating. Therefore, do not use a
wire brush or other abrasive, metallic device to clean these
sensors.
z
Verify that the face of the ParaDepth or ParaFlow sensor are
level side to side and front to back using
Qstart
XML
software.
Refer to
Chapter 4
,
Configuration and Activation
for more
information.
z
Verify that the face of the Surface Combo Sensor/Ultrasonic
Depth Sensor is horizontally level with the flow. If necessary,
reposition the sensor according to the procedures in
Chapter 5
,
Sensor Installation and Connection
.
z
Scrub the face of the AV|Gated, AV|Max and/or Peak Combo
sensor with a soft bristle brush.
Summary of Contents for 507165
Page 20: ...1 12 ADS TRITON Manual Control Drawing ...
Page 27: ...Introduction 1 19 CS6 LRD Sensor Certificate of Conformity ...
Page 29: ...Introduction 1 21 CSA Certificate of Compliance Page 1 of 7 ...
Page 30: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 2 of 7 ...
Page 31: ...Introduction 1 23 CSA Certificate of Compliance Page 3 of 7 ...
Page 32: ...1 24 ADS TRITON Manual CSA Certificate of Compliance Page 4 of 7 ...
Page 33: ...Introduction 1 25 CSA Certificate of Compliance Page 5 of 7 ...
Page 34: ...1 26 ADS TRITON Manual CSA Certificate of Compliance Page 6 of 7 ...
Page 35: ...Introduction 1 27 CSA Certificate of Compliance Page 7 of 7 ...
Page 37: ...Introduction 1 29 Sample TRITON Declaration of Conformity Page 2 ...
Page 53: ...System Overview 2 13 ExPAC XBUS ...
Page 266: ...5 60 ADS TRITON Manual z Installing the Submersion Sensor z Measuring the physical offset ...
Page 288: ...5 82 ADS TRITON Manual Topside Wall Mount Bracket Topside Sensor Bracket ...
Page 345: ...7 2 ADS TRITON Manual use of this installation guide or the installation of any ADS equipment ...
Page 358: ...Inclinometer 8 3 ...
Page 507: ...C 4 ADS TRITON Manual ...
Page 535: ...Index In 19 wiring to the monitor 6 29 XIO device parameters 4 84 ...