The analog inputs are designed to store specific data received from
third-party instruments, such as sensors, every 15 seconds.
Digital Inputs and Outputs
The monitor can support up to two digital inputs and two digital
outputs. The digital inputs receive pulses corresponding to
switches that indicate the presence or absence of a particular
condition, such as an alarm occurring through a third-party system.
The
records the state of these inputs at an interval
equivalent to the monitor’s sample rate.
The digital outputs serve as relays to notify other third-party
systems concerning certain flow conditions detected by the
. Conditions typically involve flows crossing established
thresholds that trigger events. The
refreshes the state of
these outputs every 15 seconds.
Modbus
Modbus is a protocol that enables communication to occur between
multiple devices connected to the same network. It often is used to
connect a supervisory computer with a remote terminal unit (RTU)
in supervisory control and data acquisition (SCADA) systems.
ADS uses Modbus to provide information directly to RTUs or
SCADA systems.
The ExPAC represents the interface through which Modbus
communications occur.
Summary of Contents for 507165
Page 20: ...1 12 ADS TRITON Manual Control Drawing ...
Page 27: ...Introduction 1 19 CS6 LRD Sensor Certificate of Conformity ...
Page 29: ...Introduction 1 21 CSA Certificate of Compliance Page 1 of 7 ...
Page 30: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 2 of 7 ...
Page 31: ...Introduction 1 23 CSA Certificate of Compliance Page 3 of 7 ...
Page 32: ...1 24 ADS TRITON Manual CSA Certificate of Compliance Page 4 of 7 ...
Page 33: ...Introduction 1 25 CSA Certificate of Compliance Page 5 of 7 ...
Page 34: ...1 26 ADS TRITON Manual CSA Certificate of Compliance Page 6 of 7 ...
Page 35: ...Introduction 1 27 CSA Certificate of Compliance Page 7 of 7 ...
Page 37: ...Introduction 1 29 Sample TRITON Declaration of Conformity Page 2 ...
Page 53: ...System Overview 2 13 ExPAC XBUS ...
Page 266: ...5 60 ADS TRITON Manual z Installing the Submersion Sensor z Measuring the physical offset ...
Page 288: ...5 82 ADS TRITON Manual Topside Wall Mount Bracket Topside Sensor Bracket ...
Page 345: ...7 2 ADS TRITON Manual use of this installation guide or the installation of any ADS equipment ...
Page 358: ...Inclinometer 8 3 ...
Page 507: ...C 4 ADS TRITON Manual ...
Page 535: ...Index In 19 wiring to the monitor 6 29 XIO device parameters 4 84 ...