Sensor Installation and Connection 5-51
8.
Spot drill the pipe wall through the hole, install a ¼-inch x 2
¼-inch (M6 x 55-mm) anchor bolt, and secure the band to the
anchor bolt with a washer and nut.
Note:
Make sure the submerged portion of the band is
flush with the pipe wall. If it is not, remove the band and
conform the band to the pipe.
9.
Install a ¼-inch x 2 ¼-inch (M6 x 55-mm) anchor bolt, washer,
and nut below the flow surface 30 to 80 mm away from the
underwater sensor on each side. This will hold the sensor
securely against the pipe wall and prevent the end of the band
from twisting in the flow or catching debris.
10.
Conform the portion of the band above the flow surface to the
pipe wall, and install an ¼-inch x 2 ¼-inch (M6 x 55-mm)
anchor bolt, nut, and washer every 12 to 24 inches (305 to 610
mm) up to the top of the band.
Completed ½-band mount in pipe
11.
Measure the physical offset for the sensor by manually
measuring the depth of the flow from the bottom of the pipe to
the flow surface and then measuring the distance from the
nose
(i.e., front end at the pipe surface) of the sensor to the flow
surface. Subtract the second measurement from the initial
depth of flow to determine the physical offset.
Summary of Contents for 507165
Page 20: ...1 12 ADS TRITON Manual Control Drawing ...
Page 27: ...Introduction 1 19 CS6 LRD Sensor Certificate of Conformity ...
Page 29: ...Introduction 1 21 CSA Certificate of Compliance Page 1 of 7 ...
Page 30: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 2 of 7 ...
Page 31: ...Introduction 1 23 CSA Certificate of Compliance Page 3 of 7 ...
Page 32: ...1 24 ADS TRITON Manual CSA Certificate of Compliance Page 4 of 7 ...
Page 33: ...Introduction 1 25 CSA Certificate of Compliance Page 5 of 7 ...
Page 34: ...1 26 ADS TRITON Manual CSA Certificate of Compliance Page 6 of 7 ...
Page 35: ...Introduction 1 27 CSA Certificate of Compliance Page 7 of 7 ...
Page 37: ...Introduction 1 29 Sample TRITON Declaration of Conformity Page 2 ...
Page 53: ...System Overview 2 13 ExPAC XBUS ...
Page 266: ...5 60 ADS TRITON Manual z Installing the Submersion Sensor z Measuring the physical offset ...
Page 288: ...5 82 ADS TRITON Manual Topside Wall Mount Bracket Topside Sensor Bracket ...
Page 345: ...7 2 ADS TRITON Manual use of this installation guide or the installation of any ADS equipment ...
Page 358: ...Inclinometer 8 3 ...
Page 507: ...C 4 ADS TRITON Manual ...