Configuration and Activation 4-51
z
Pipe Height
This field displays the pipe height at the
monitoring point, based on the installation table.
This
parameter is not editable from this location.
Note:
Under normal conditions, the remaining
parameters corresponding to the
AV|Max
or
Peak Combo
device
should not require modification. However, if
additional adjustments are necessary, the following
sections provide a detailed description of each parameter.
Ultrasonic tab
–
AV|Max or Peak Combo
Edit the following parameters corresponding to the upward-looking
ultrasonic depth sensor in the AV|Max or Peak Combo Sensor:
z
Enable
Select this checkbox to ensure the monitor begins
taking upward ultrasonic depth readings at the designated
interval upon activation. This option is selected by default.
z
Flow Type
Select the option that best reflects the kind of
flow conditions that typically occur at the monitoring point
from the drop-down list:
Typical
Flow exhibits a typical diurnal pattern.
This is
the default setting.
Wet/Stagnant
Flow remains in the pipe but moves only
during wet weather events.
Usually Dry
Pipe typically remains dry, except under
wet weather conditions.
z
Electronic Offset
Enter the difference that exists between
the depth sensor readings and the manually measured depth.
The default value is 0.
z
Deadband
Select the distance from the sensor face within
which readings received will be ignored. The default value
(Auto) represents a percentage of the flow depth and should be
sufficient under normal circumstances. It also is the best
option for handling shallow flows. However, consider another
value when the sensor readings reveal a potential problem with
false dropouts. Choose a value for the deadband that is
sufficiently below the minimum depths that legitimately occur
Summary of Contents for 507165
Page 20: ...1 12 ADS TRITON Manual Control Drawing ...
Page 27: ...Introduction 1 19 CS6 LRD Sensor Certificate of Conformity ...
Page 29: ...Introduction 1 21 CSA Certificate of Compliance Page 1 of 7 ...
Page 30: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 2 of 7 ...
Page 31: ...Introduction 1 23 CSA Certificate of Compliance Page 3 of 7 ...
Page 32: ...1 24 ADS TRITON Manual CSA Certificate of Compliance Page 4 of 7 ...
Page 33: ...Introduction 1 25 CSA Certificate of Compliance Page 5 of 7 ...
Page 34: ...1 26 ADS TRITON Manual CSA Certificate of Compliance Page 6 of 7 ...
Page 35: ...Introduction 1 27 CSA Certificate of Compliance Page 7 of 7 ...
Page 37: ...Introduction 1 29 Sample TRITON Declaration of Conformity Page 2 ...
Page 53: ...System Overview 2 13 ExPAC XBUS ...
Page 266: ...5 60 ADS TRITON Manual z Installing the Submersion Sensor z Measuring the physical offset ...
Page 288: ...5 82 ADS TRITON Manual Topside Wall Mount Bracket Topside Sensor Bracket ...
Page 345: ...7 2 ADS TRITON Manual use of this installation guide or the installation of any ADS equipment ...
Page 358: ...Inclinometer 8 3 ...
Page 507: ...C 4 ADS TRITON Manual ...
Page 535: ...Index In 19 wiring to the monitor 6 29 XIO device parameters 4 84 ...