The following table shows the connections to the DeviceNet connector:
Function
Wire color
Signal name
I/O pin
DeviceNet network negative power ( 0 V)
black
V-
1
DeviceNet communication network terminal
(low)
blue
CANL
2
Network cable shield
bare
Shield
3
DeviceNet communication network terminal
(high)
white
CANH
4
DeviceNet network positive power ( 24 V DC)
red
V+
5
This connector is internally connected with the optional DeviceNet board
(DSQC1006). The X17 is the predefined connection to the DeviceNet board in main
computer for the customer.
Tip
The DeviceNet network needs to be powered by a separate 24 V power supply,
or the DeviceNet function will not work.
See
Application manual - DeviceNet Master/Slave
,
3HAC066562-001
, section
"Hardware overview" for more information on how to connect 24 V to the
DeviceNet network.
For connection details, see
Circuit diagram - OmniCore C30
,
Circuit
diagram - OmniCore C30 for IRB 14050
,
Circuit diagram - OmniCore C30 for CRB
15000
,
3HAC059896-009
,
3HAC063898-009
,
3HAC072448-009
.
X45 - IP20 power outlet connector (option)
A
xx1700001064
IP20 Power outlet connector
A
Continues on next page
124
Product manual - OmniCore C30
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
3.5.8 Descriptions for connectors
Continued
Summary of Contents for OmniCore C30
Page 1: ...ROBOTICS Product manual OmniCore C30 ...
Page 562: ...This page is intentionally left blank ...
Page 566: ...This page is intentionally left blank ...
Page 574: ...This page is intentionally left blank ...
Page 604: ......
Page 605: ......