3.5.4 Fitting the connector
General
This section describes how to manufacture a cable for connecting the main power
to the controller.
xx1700000742
Detailed view
A
B
C
D
E
F
G
xx1900000058
Description
Gland
A
Crown clamp
B
Shielding element
C
Distance sleeve
D
Contact socket
E
Insulation inserts
F
Housing
G
Specifications
The following describes the cable requirements for the main power connection to
the OmniCore C30 controller.
Description
Component
Flexible oil resistant rubber
Cable type
3C x 1.5 mm
2
or AWG14
Cable area