5.3.5 Replacing the process connectors
Location
The illustration shows the location of the process connectors in the controller.
xx1800000737
Note
To confirm whether this unit is available in your controller, see chapter
.
If this unit is not available in your controller, ignore the related procedure to this
unit when you do any maintenance or repair work.
Required spare parts
Note
The spare part numbers that are listed in the table can be out of date. See the
latest spare parts of the OmniCore C30 via myABB Business Portal,
.
Note
Article number
Spare part
3HAC063601-001
Harness DeviceNet/Harness 24V
ext. cover plate
DSQC1004
3HAC062150-001
Harness DeviceNet connection
Mating CONN for IP20 DeviceNet
connector
3HAC064901-001
Connector assembly Single-row
female
Continues on next page
Product manual - OmniCore C30
455
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.