Note/Illustration
Action
Screws: Torx pan head screw M4x8 (4 pcs)
A
xx1800001188
Cable clip
A
Secure the optional power supply with
the screws.
3
Connect:
•
A1.X7 - T5.X1
Note
The connector on the AC_in cable
(
3HAC061099-001
) is fastened to the
cable clip in the illustration when the
power supply optional is not selected.
4
Refitting the axis computer to the frame
Note/Illustration
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
1
Location of wrist strap button:
xx1800000683
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
2
Reconnect and secure the screw:
•
K6.X4, K6.X5 - SMB.
3
Continues on next page
164
Product manual - OmniCore C30
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
3.7.4 Installing the power supply optional device and the harness 24 V extension
Continued