![ABB OmniCore C30 Product Manual Download Page 311](http://html.mh-extra.com/html/abb/omnicore-c30/omnicore-c30_product-manual_3131311.webp)
Note/Illustration
Action
Location of wrist strap button:
xx1800000683
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
2
xx1800000938
Connect the adapter cable to the digital
base.
•
K5.1.X5 - Harness adapter
Stick the other connector onto the side
of the digital base with the self-adhesive
part.
3
Connect the connectors between the
adapter cable (K5.1.X5 - Adapter) and
the adaptor cable (Adaptor -
A2.X4/K4.X7).
Note
If the Ethernet extension switch is in-
stalled, connect and disconnect the ad-
apter cable (A2.X4/K4.X7) to/from K4.X7.
If the Ethernet extension unit slot cover
is installed, connect and disconnect the
adapter cable (A2.X4/K4.X7) to/from
A2.X4.
4
Continues on next page
Product manual - OmniCore C30
311
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.2.7 Replacing the scalable I/O unit
Continued