![ABB OmniCore C30 Product Manual Download Page 235](http://html.mh-extra.com/html/abb/omnicore-c30/omnicore-c30_product-manual_3131235.webp)
Note/Illustration
Action
Location of wrist strap button:
xx1800000683
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
2
Reconnect and secure the screw:
•
K6.X4, K6.X5 - SMB.
3
Screws: Torx pan head screw M4x8 (4 pcs)
xx1800000476
Fit the axis computer bracket and secure
the screws.
4
Reconnect:
•
K6.X11 - A1.X3
•
K6.X2 - A2.X9
•
K6.X1 - K2.X3
5
Concluding procedure
Note/Illustration
Action
Refitting the controller covers on page 227
.
Refit the covers.
1
Perform the function tests to verify that
the safety features work properly, see
2
Product manual - OmniCore C30
235
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.2.2 Replacing the axis computer
Continued
Summary of Contents for OmniCore C30
Page 1: ...ROBOTICS Product manual OmniCore C30 ...
Page 562: ...This page is intentionally left blank ...
Page 566: ...This page is intentionally left blank ...
Page 574: ...This page is intentionally left blank ...
Page 604: ......
Page 605: ......