Note/Illustration
Action
Screws: Torx pan head screw M4x8 (4 pcs)
xx1800000489
Fit the robot signal exchange proxy and
secure the screws.
Note
Avoid colliding with the frame of the
controller.
3
xx1800000971
Insert the cable ties into the locking
holes.
4
Reconnect:
•
K2.X8 - A2.X6
•
(option): K2.X2 - K4.X8, A2.X1
•
K2.X12 - A2.K3.X6, A2.K3.X7
•
K2.X10 - A1.X13
•
K2.X21 - TempSensor
•
K2.X4 - A1.X9
•
K2.X3 - K6.X1, A2.K3.X1, K5.1.X4,
K7.X1
•
K2.X1 - T2.X2
18
•
K2.X1 - X107
19
•
K2.X17 - G2.X1, G1.X2
•
K2.X6, K2.X11 - A1.X2
•
K2.X7, K2.X22 - Harn. LV robot
power (X1)
•
K2.X9 & X13 - FlexPendant (X4)
5
18 Not available for CRB 15000 controller.
19 Only used for CRB 15000 controller.
Continues on next page
Product manual - OmniCore C30
287
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.2.4 Replacing the robot signal exchange proxy
Continued