6.3.2 Troubleshooting the FlexPendant
Description
The FlexPendant communicates with the main computer. The FlexPendant is
physically connected to the panel board. The cable contains the +24 V supply, two
enabling device chains and emergency stop.
Procedure
The procedure below describes what to do if the FlexPendant does not work
correctly.
Note
Action
See
Operating manual - Omni-
Core
.
Try resetting the FlexPendant using the reset
button located next to the USB port.
1
Note
If protective gloves are used, these
must be compatible with touch-
screens when using the FlexPend-
ant.
If the FlexPendant is not responding or does not
operate correctly, see
necting the FlexPendant on page 517
.
2
Check the cable for connections and integrity.
3
Check the 24 V power supply.
4
Read the error event log message and follow any
instructions of references.
5
For more information on the FlexPendant, see
Operating manual - OmniCore
.
Product manual - OmniCore C30
529
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
6 Troubleshooting
6.3.2 Troubleshooting the FlexPendant
Summary of Contents for OmniCore C30
Page 1: ...ROBOTICS Product manual OmniCore C30 ...
Page 562: ...This page is intentionally left blank ...
Page 566: ...This page is intentionally left blank ...
Page 574: ...This page is intentionally left blank ...
Page 604: ......
Page 605: ......