HVC
‐
PD
E
‐
Bus
Charger
Installation
Guide
Document: V1.2 / Document No.: 6AGA000008-0629-EN | Date: 06-30-2022 Page
84
of
146
CAN cable connection in
primary HVC 150
:
A Terminal
block
B CAN cable from secondary 1 HVC 150S
1. Move the cable towards the terminal block (A).
2. Strip 0.43 Inch of the insulation from the ends of the wires.
3. Crimp a ferrule onto the end of the wire.
4. Loosen the connector screws.
5. Insert the wires into the connectors, see table below:
Functional description
Connector
Wire color
CAN H In
X286-1
Brown
CAN L Out
X286-2
White
CAN GND
X286-3 or Shield Can In
Shield
See also Appendix H
Signal connection diagram
.
6.
Tighten the connector screws with a tightening torque of 1.0 ft-lb.