8.5. Environment
Environment specification Power Cabinet
Ingression protection
IP54
Temperature range – Operation
-35 ºC to +45
⁰
C
Temperature range – Storage
-10 ºC to +70
⁰
C
Humidity
5 % to 95 %, RH – non-condensing
Airflow 1450
m
3
/h
Pressure drop
300 pA
Altitude 6561.68
ft
(max.)
Storage conditions
Indoors, dry
Environment specification ACS Control Module
Ingression protection
IP65
Temperature range – Operation
-35 ºC to +45
⁰
C
Temperature range – Storage
-10 ºC to +70
⁰
C
Humidity
5 % to 95 %, RH – non-condensing
Altitude 6561.68
ft
(max.)
Storage conditions
Indoors, dry
Environment specification Charge pole
Ingression protection
IP54
Temperature range – Operation
-35 ºC to +45
⁰
C
Temperature range – Storage
-10 ºC to +70
⁰
C
Humidity
5 % to 95 %, RH – non-condensing
Altitude 6561.68
ft
(max.)
Maximum operational wind speed
44.7 mph (8 Bft)
Maximum deflection
89.5 mph (14 Bft)
Storage conditions
Indoors, dry
CAUTION
Warranty
Warranty will be considered void when the HVC-PD E-Bus Charger is
damaged while badly stored at the customer's location.
8.6. Certifications
Certifications for complete system
UL 2202
HVC 150: Certificate No. TU 72180445
ACM Certificate No. TU 72180799 02
CSA C22.2 No. 107.1—16
HVC150 Certificate No. CA 972180446 01
ACM Certificate No. CA 72180446 02
Class of protection
1 with GND connection