HVC
‐
PD
E
‐
Bus
Charger
Installation
Guide
Document: V1.2 / Document No.: 6AGA000008-0629-EN | Date: 06-30-2022 Page
114
of
146
6. Route the RFID Power cable (C) through gland #10 to connector block X4, with sufficient
cable length (do not make the cable routing too tight, or too loose).
7. Tighten the nut of the gland to secure the RFID Power cable.
8. Strip the insulation from the cable.
9. Strip 0.43 Inch of the insulation from the ends of
only the Brown and Blue wire!
10. Crimp a ferrule onto the end of the Brown and Blue wire.
11. Cut the other wires,
except the Brown and Blue wire
, at the end of the striped insulation
of the cable.
12. Loosen the connector screws.
13. Insert the wires into the correct connectors, see table below:
Functional description
Connector
Wire color
24 V RFID
X4-41
Brown
GND RFID
X4-42
Blue
14. Tighten the connector screw with a tightening torque of 1.0 ft-lb.
5.16.12.
Connect the Interlock cable from the Power Cabinet
Preconditions:
Tools: wire cutter, wire stripper pliers, screwdriver, ferrules, crimp pliers.