Cabinets with Q968: the installation site altitude in operation is 0 to 2000 m.
• Close the disconnector and switch the power on.
• Test the operation of the STO function when the
motor is stopped:
- Give a stop command for the drive (if running)
and wait until the motor shaft is at standstill.
- Activate the STO circuit and give a start
command for the drive.
- Ensure that the motor stays at standstill.
- Deactivate the STO circuit.
• Restart the drive and check that the motor runs
normally.
• Test the operation of the STO function when the
motor is running:
- Start the drive and ensure that the motor is
running.
- Activate the STO circuit.
- Ensure that the motor stops and the drive trips.
- Reset the fault and try to start the drive.
- Ensure that the motor stays at standstill.
- Deactivate the STO circuit.
• Restart the drive and check that the motor runs
normally.
LED
Indication
V309 (red)
Prevention of unexpected start (Q950) or Safe torque off (Q968) is
ON.
Operation
installed for stationary use
Installation site altitude
[...]
Cabinets with Q968:
0 to 2000 m
Action
Additional information
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for ACS800-07-0610-3
Page 4: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 7: ...Update Notice 3 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 10: ...Update Notice 6 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...