 The filter loading indicator is for particulates only. It does not provide any information about 

gas and vapour service life. Leave the contaminated area immediately if you taste or smell 
contaminants.

Use in the 'power-off' state is not normal, little or no protection is provided and a build up 
of carbon dioxide and depletion of oxygen within the Headtop may occur, vacate the 
contaminated area immediately.

Take care to prevent the breathing tube from becoming looped around protruding objects. If 
during use, the airflow into the Headtop stops and the alarm sounds, vacate the contaminated 
area immediately and investigate the cause (please see fault finding).

NOTE: The ‘in-use’ life of the product will vary with frequency and conditions of use.

 In 

everyday use, the expected 'in-use' life is 3-5 years. Some extreme conditions may result in 
deterioration over a shorter period. The product must be stored and maintained as stated below.

Note:

 Do not expose battery pack to temperatures above 54°C. The Powered Air Turbo battery 

alarm will activate if battery pack temperature reaches 54°C while the Powered Air Turbo is in 
use. The Powered Air Turbo will shut down if the battery pack temperature exceeds 60°C.

^

 Do not use the batteries outside of the recommended temperature limits.

DOFFING

Do not remove the headtop or turn off the air supply until you have vacated the 
contaminated area.

1. Lift the Headtop off the head.
2. Switch off the Powered Air Turbo by pressing the power button for 2 seconds.
3. Unbuckle the waist belt. If required, remove the belt from the Powered Air Turbo by lifting the 
lower, centre portion of the belt over the locking edges and sliding the belt down (see Fig 16).
4. If required, remove the filter. Press the filter latch and pull the filter away from the Powered Air 
Turbo (see Fig 17).

Note:

 When removing the filter, hold the Powered Air Turbo facing downwards (cover towards 

the ground) to help minimise the potential for contamination of the motor/fan.
To remove the cover from the filter, hold the filter upside down and pull out on the blue tab at the 
bottom of the filter cover to unlatch it from the filter (see Fig 18).  Pull the cover down and away 
from the filter.

Note:

 Filters may be stored attached to the Powered Air Turbo however, to help maintain 

service life and keep the system clean, the Powered Air Turbo should be stored in a sealed 
container. The system must also be fully inspected prior to next use. Alternatively, the filter may 
be stored in its original packaging.

If the respirator has been used in an area that has caused it to become contaminated 
with a substance requiring special decontamination procedures it should be placed in a 
suitable container and sealed until it can be decontaminated or discarded.

CLEANING INSTRUCTIONS

Use a clean cloth dampened with a mild solution of water and liquid household soap. Do not use 
petrol, chlorinated degreasing fluids (such as trichloroethylene), organic solvents or abrasive 
cleaning agents to clean any part of the equipment. To disinfect use wipes as detailed in 
Reference Leaflet.

^

 Keep inner filter seal clean.

^

 Never attempt to clean filters by knocking or blowing out accumulated material.

The spark arrestor can be cleaned using water and liquid household soap. Completely dry the 
spark arrestor with a clean cloth. If it cannot be cleaned or is damaged then it should be 
replaced. The Powered Air Turbo can be immersed or put in a respirator washer for cleaning. 
Filters must be removed and the air inlet and air outlet cleaning and storage plugs must be 
inserted into the Powered Air Turbo first (see Fig 19). Plugs should be inspected for damage and 
wear prior to each use. Worn or damaged seals must be replaced. Plugs should be replaced 
every 30 uses or annually, whichever comes first. Water temperature should not exceed 50°C.

Note:

 Powered Air Turbos which have been dropped or damaged should not be immersed or 

put in a respirator washer due to potential water ingress. The battery can also be immersed for 
cleaning. Remove the battery from the Powered Air Turbo and use a cleaning cover (available 
as an accessory) to keep the contacts free from corrosion (See Fig 20).

Note:

 There are two locking loops on the battery cleaning cover. The smaller loop position is for 

use with the standard capacity battery (see Fig 21A), the larger loop position is for use with the 
high capacity battery (see Fig 21B).

^

 Do not immerse without the battery storage and cleaning cover installed.

^

 Do not immerse battery if damaged.

If water is found between the battery and cleaning cover after immersion, discard cleaning cover 
and replace. The battery contacts may be cleaned with a mild solution of water and pH neutral 
detergent. Ensure that the contacts are clean and dry before storage and use.

MAINTENANCE

General

Maintenance, servicing and repair must only be carried out by properly trained personnel.

^

 Use of unapproved parts or unauthorised modification could result in danger to life 

or health and can invalidate any warranty.

_

_

_

Display

Display

Sounder Vibrate Comments

Warnings

FAULT FINDING

Sounder Vibrate

Explanation

On 
(Normal 
Operation)

On (sleep 
mode)

Low 
Battery

(LED = red)

Low Flow

Tight-Fitting 
indicator

(example, 
LED = green)

(example, 
LED = green)

(example, 
LED = green)

(LED = green)

(LED = green)

(LED = green)

Charge status of battery (less than 80% in 
example)

New filter in example

Standard flow selected

Medium flow selected

High flow selected

Standard flow selected

Medium flow selected

High flow selected

Tight-fitting mode activated – when 
facepiece is connected via appropriate 
breathing tube

Partially loaded filter in example

Note:

 For some systems, the inherent 

pressure drop e.g. of headtop and/or filter, 
will mean that not all LEDs will be lit, even for 
new filters

 x 1 

when 

selected

 x 2 

when 

selected

 x 3 

when 

selected

Key:

= Slow Flash

= Short Beep

Low Flow 
and Battery

(LED = red)

Airflow Check

Before use

(LEDs = red)

See above

Yes

Yes

Yes

1. Charge battery

2. Battery not correctly installed.

Remove and reinstall battery.

3. Battery has exceeded service life.

Install a new, fully charged battery.

4. Battery pack has exceeded operating 

temperature of 54°C. Remove to cooler 

location.

5. Contaminant on battery contacts.

Ensure battery contacts are clean.
1. Hose blocked. Clear/replace hose.

2. Filter covered. Clear obstruction.

3. Filters blocked. Replace filters and 

pre-filter/spark arrestor if used.

4. Temperature has exceeded operating 

range. Remove to cooler location.

WHAT

WHEN

Alarm Check

General Inspection
Cleaning

Filter cover replacement (if 
used)

Before use

After use

Replace with each new filter.
Cover may be reused if undamaged and attaches 
correctly.

Before use - Monthly if not in regular use

Disposal

If disposal of parts is required this should be undertaken in accordance with local health and 
safety and environmental regulations.

^

 Dispose of lithium ion battery packs according to local environmental regulations. Do not 

dispose of in standard waste bins, in a fire or send for incineration.

Battery Charging

Select an approved charger kit and refer to the user instructions provided with the kit.
Batteries should be charged after each use.

^

 Do not charge batteries with unapproved chargers, in enclosed cabinets without ventilation, 

in hazardous locations or near sources of high heat.

^

 Do not charge the batteries outside the recommended temperature range of 0 to +40°C.

The battery may be left on the charger. However, for long term storage of the batteries, 3M 
recommends that they are stored off the charger at approximately 30-50% charge. The battery 
should never be left in a discharged state. The batteries are designed to provide approximately 
250 charge/discharge equivalents, during the first year of service, while maintaining at least 80% 
of their original capacity.      

= Slow Flash

= Long Intermittent Beep

Key:

_

_

_

_

_

_

_

_

_

_

_

_

_

_

_

_

_

6

Summary of Contents for Versaflo TR-602E

Page 1: ...268 in 100 000 XX x XX mm XX x XX in Itarus House Tenter Road Moulton Park Northampton NN3 6PZ Need help Contact us 44 0 1604 168100 mail itarus com www itarus com Powered by Print Spec No Stock No T...

Page 2: ...sa o TR 602Epuhur L 3M Versa o motoriz tais gaisa respirators TR 602E l 3M Versa o Oro ltravimo renginys TR 602E r 3M Versa o Sistemul cu presiune pozitivaTR 602E u 3M Versa o TR 602E c 3M Versa o Pow...

Page 3: ...2 3 4 5C 8 5A 5B 7 1 6 2...

Page 4: ...9 10 14 13 11 15 12 1 2 3 4 5 6 3...

Page 5: ...19 20 16 17 18 21B 21A 1 2 2 1 1 2 4...

Page 6: ...ngthecornersandlatches Immediatelyreplaceif damaged Ifthefilterhasbeenmishandledordropped re inspectfully Ifyouhaveanyconcern contact 3MTechnicalServiceforguidance Alwaysproperlyinstallthefilterintoth...

Page 7: ...vebeendroppedordamagedshouldnotbeimmersedor putinarespiratorwasherduetopotentialwateringress Thebatterycanalsobeimmersedfor cleaning RemovethebatteryfromthePoweredAirTurboanduseacleaningcover availabl...

Page 8: ...urservicelife STORAGEANDTRANSPORTATION Ensurefiltersandbatteriesarestoredinaccordancewithinstructionsbelow Theseproducts shouldbestoredinthepackagingprovidedindry cleanconditionsawayfromdirectsunlight...

Page 9: ...univeaudelamer etdelatemp raturedel air Avanttouteutilisation v rifiezle d bitd air l aidedutuyauindicateurded bitd air commeindiqu lafigure6 Faites fonctionnerl unit turbo ventilationassist ependant1...

Page 10: ...ommageetd usure Remplaceztoutjointus ouendommag Remplacezlesbouchons annuellementet entout tatdecause toutesles30utilisations Latemp raturedel eaunedoit pasd passer50 C Remarque Lesunit sturbo ventila...

Page 11: ...s Batteriehautecapacit moinsde4 5heures Conditionsd utilisation 10 C 54 C 54 Climit parbatterie Poids aveclabatterie conomiquestandardmaissanslaceinturenilesfiltres TR 602E 1120g Indicedeprotection IP...

Page 12: ...tumdennotwendigenLuftvolumenstromzuliefern Die Gebl seeinheitverf gt berdies bereineautomatischeH henkompensation dieEinsatzh he Meter berdemMeeresspiegel undLufttemperaturber cksichtigt Bittepr fenSi...

Page 13: ...erteLaschenach au en s Abb 18 ZiehenSiedenFilterdeckelvomFilterab Achtung DieGebl seeinheitkannauchmiteingesetztenFilterngelagertwerden UmdasSystemsauber undlanglebigzuhalten wirdempfohlen diesesinein...

Page 14: ...alleKontaktesauberundtrockensind 3 BatteriehatkeineLadung LadenSiedie Batterie FehlfunktionderSorfware SchaltenSiedie Gebl seeinheitausumdenAlarmzul schen NehmenSiedieBatterieausderGebl seeinheit undw...

Page 15: ...tratonellaFigura2 1barra menodel20 5barre dall 80 al100 Un identicoindicatoredistatodellabatteria presenteanchesuldisplaydell Unit Turbo InserirelebatteriecomemostratonellaFigura3 L agganciodevescatta...

Page 16: ...gni30utilizzio annualmente asecondadiqualescadenzasiverifichiprima Latemperaturadell acquanon devesuperarei50 C Nota leUnit Turbochesonocaduteorisultanodanneggiatenondevonoessereimmersein acquaomessen...

Page 17: ...batteria completamentecarica 4 Ilgruppobatteriehasuperatola temperaturaoperativadi54 C Rimuovereelasciareraffreddare 5 Presenzadicontaminazionesui contattidellabatteria Assicurarsicheicontattidellabat...

Page 18: ...nlaFig 3 Lapesta a debeencajarsehastaoirun click Tireconsuavidaddelabater aparaconfirmarqueest correctamenteinsertada Filtros Seleccioneunfiltroaprobado Porfavorconsulteelmanualdereferenciadelmotovent...

Page 19: ...a disponiblecomoaccesorio para mantenerloscontactoslibresdecorrosi n VerFig20 Nota Haydosanillasdecierreenlacubiertadelimpiezadelabater a Laanillapeque aes paralautilizaci ndelabater aest ndar verFig2...

Page 20: ...trosbloqueados Sustituir ltrosy pre ltros protectoresdechispassise hanutilizado 4 Latemperaturaexcedeelrangode operaci n Moveraunlugarm sfr o 1 Loscontactosdelabater aest n averiados Comprobarcontacto...

Page 21: ...jgoedvastzit Filters Selecteereengoedgekeurdfilter ZiereferentiefolderTR 602Emotorunitvooreenlijstmet3M goedgekeurdefilters Derondebinnendichtingisdeeerstedichtingtussendefilterende motorunit Debuiten...

Page 22: ...er Ook debatterijkanwordenondergedompeldomzetereinigen Haaldebatterijuitdemotoruniten gebruikeenreinigingskap verkrijgbaaralsaccessoire omcorrosieaandecontactente voorkomen zieafbeelding20 Opmerking d...

Page 23: ...opeenkoelere plek 5 Vuilopbatterijcontacten Reinigdebatterijcontacten 1 Slangverstopt Leeg vervangdeslang 2 Filterbedekt Verwijderhetobstakel 3 Filtersgeblokkeerd Vervang ltersen voor lter vonkenvange...

Page 24: ...hov Inspekterafiltretsplasth ljenoga inklusiveh rnochhakar Ers ttdetomedelbartomdet r skadat Inspekterafiltretnogaomdetharhanteratsfelaktigtellertappats Kontakta3M stekniska kundtj nstomduharn grafr g...

Page 25: ...gning venbatterietkanreng rasivatten Avl gsnabatterietfr nfl ktenhetenochanv ndettreng ringsskydd tillg ngligtsomtillbeh r f rattskyddakontakternamotrost sefigur20 OBS Detfinnstv l s glorp batterietsr...

Page 26: ...lj ochejidirektsoljusellerin rhetenav v rmek llor bensin ellerl sningsmedels ngor F rvarainteutanf rtemperaturomr de 30 Ctill 50 Cellermedenluftfuktighet ver90 Omproduktenskalagrasunderenl ngreperiodi...

Page 27: ...ing 3 Udv lgetgodkendtb lte seindl gsseddelmedlisteover3Mgodkendteb lter Turboenheden harfirel sestudse sefig 8 ogb ltethar4tilsvarendehuller sefig 9 Tilpasdefirel sestudsei b ltetshuller sefig 10 Try...

Page 28: ...eskyttelsesfaktor Sevenligstbrugsanvisningenfordenrelevantehovedel Luftstr mskarakteristik Fabrikantensminimumdesignflow MMDF 170l min Standardluftflow Nominelt190l min Mediumluftflow Nominelt205l min...

Page 29: ...et Hvisfiltereterfeilh ndtert ellermistetigulvet m detkontrolleresn ye Hvisdueritvilkandu kontakte3Mformerinformasjon Filteretm alltidplasseresriktigibatteriturboen Passp atturboeneravsl tt For settei...

Page 30: ...ller delagtforseglingerm byttes Proppenem byttesetter30gangers bruk ellerhvert r avhengigavhvasomkommerf rst Vanntemperaturenm ikkeoverskride 50 C Merk Batteriturboersomermistetigulvet ellersomer dela...

Page 31: ...r d Lav luftmengde Symbol Definisjon M ikke utsettesforild oppbevaresiandretemperaturerenndeanbefalte Lukter oppdaget Lav luftmengde oglavt batteriniv Ingen luftstr mog ingenAlarm System Alarm LEDlys...

Page 32: ...leen Varmista ett akkuyksikk onlukittunutpaikoilleen vet m ll sit varovasti Suodattimet Valitsehyv ksyttysuodatin KatsoTR 602Epuhallinyksik ntuote esitteest luettelo3M n hyv ksymist suodattimista Sise...

Page 33: ...ivuosittain ensint yttyv onm r v Vedenl mp tilaeisaaylitt 50 C Huomaa Pudonneitataivaurioituneitapuhallinyksik it eisaaupottaaveteentai hengityksensuojaimienpesukoneeseenvedensis np syvaarantakia Akku...

Page 34: ...ku tyhjenem ss LED punainen Matala virtaus Symboli Selitys l altistatulelle s ilyt suositellunl mp tilarajanulkopuolella Hajua havaitaan Matala virtausja akku tyhjenem ss Ei ilmavirtaust a ei h lytyst...

Page 35: ...amb mexisteumindicadordebateria id nticonomostradordoMotoventilador Encaixeabateria conformeilustradonaFig3 A linguetadeveencaixarcomumcliqueaud vel Puxeabateriacomcuidadoparaconfirmarque est bloquead...

Page 36: ...ralimpeza RetireabateriadoMotoventiladoreuse umacoberturadelimpeza dispon velemacess rio paraevitaracorros odoscontactos ver Fig20 Nota existemdoisloopsdebloqueionacoberturadelimpezadabateria Aposi od...

Page 37: ...ilizados 4 Atemperaturaexcedeuolimitede funcionamento Coloque anumlocal maisfresco 1 Ocontactodabaterianoconjuntoda bateriaest partido Veri queocontacto esubstituaabateriaseestaestiver dani cada 2 Con...

Page 38: ...ersaflo TR 602E a b c d 3 Hellas 3M Versaflo TR 602E EN12941 TR 630 TR 632 standard TR 602E IDLH 19 5 3 a b c d e f 3 3 3 TR 602E 3M 1 2 1bar 20 5bar 80 100 3 TR 602E 3M 3 4 4 5A 1 2 3 4 cut outs 5B 5...

Page 39: ..._ _ _ _ _ On LED LED LED LED LED LED 80 LED x1 x2 x3 2 3 3 8 9 10 11 12 13 4 5 1 14 15 1 30 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 5 54 C 54 C 60 C 1 2 2 3 16 4 17 18 19 30 50 C 20 21A 21B 38...

Page 40: ...Li ion 11 1V 7 8AhLi ion LED LED LEDs LED 1 2 3 4 54 C 5 1 2 3 4 1 2 3 3M 20 C 3 5 4 5 10 C 54 C 54 C TR 602E 1120g IP IP54 5 4 IP67 6 7 1 89 686 EEC CE 10 ECType Examination 11 EC BSI KitemarkCourt D...

Page 41: ...wspos bpokazany narys 2 1belka poni ej20 5belek 80 100 Identycznywska nikstanuna adowania akumulatoraznajdujesi te nawy wietlaczujednostkinap dowej Zainstalowa akumulatorw spos bpokazanynarys 3 Zatrza...

Page 42: ...arm d wi kowyurz dzeniaw czysi wmomencie gdypodczaseksploatacjijednostkinawiewowej Turbotemperaturaakumulatoraosi gnie54 C Jednostkanap dowawy czysi je eli akumulatorulegnienagrzaniudotemperaturypowy...

Page 43: ...n Ustawieniestandardoweprzep ywu nominalnie190l min Ustawienie rednieprzep ywu nominalnie205l min Ustawieniezwi kszonegoprzep ywunominalnie220l mon Zakrespracywzgl demwysoko ci od 100mdo3050m Specyfik...

Page 44: ...tmegnyomvahat rozhatjameg l sda2 br t 1s v 20 alatt 5s v 80 100 Egy n ll akkumul tor llapotjelz asz rtleveg sturb egys genis megtal lhat Helyezzebeazakkumul tort l sda3 br t Aretesznekhallhat ankattan...

Page 45: ...t fed n Akisebbikanorm l kapacit s akkumul torhaszn lat hoz l sd21A bra anagyobbpediganagykapacit s akkumul torhozval l sd21B bra Nemer tsev zbeazakkumul tortatiszt t fed alkalmaz san lk l S r ltakku...

Page 46: ...lete meghaladtaaz zemi54 C rt ket Vegyeki stegyeh v sebbhelyre 5 Szennyezettakkumul tor rintkez k Gy z dj nmegr la hogyaz akkumul tor rintkez sipontjaitiszt k 1 At ml elt m d tt Tiszt tsameg t vol tsa...

Page 47: ...layiPoweredAirTurbojednotky P ipevn tebateriidleobr zku 3 Z padkabym lasly iteln zapadnout Jemn zat hn tezabateriovoujednotku abystese p esv d ili ejespr vn um st na Filtry Vyberteschv len filtr Prost...

Page 48: ...nesm b tpono enynebovlo enydo podlo kyrespir torukv limo n muvniknut vody Beterietakt m eb tpono enakv li i t n Vyjm tebateriizjednotkyapou ijte i t n krytu k font id SLOVNIK_HIGHLIGHT gt dispozici fo...

Page 49: ...im ln v dr baterie hodiny Displej Akustick signaliz tor Vibrov n Koment e V strahy MO N Z VADY Skoro vybit baterie LED erven N zk pr tok Symbol Definice Zamezte vystaven ohni skladov n mimodoporu en r...

Page 50: ...mnezatla teakumul tor abystesauistili ejezaisten namieste Filtre Vyberteschv len filter Zoznamfiltrovschv len chspolo nos ou3Mn jdetevreferen nom let kukfiltra no ventila nejjednotkeTR 602E Vn torn ok...

Page 51: ...d atoho onastanesk r Teplotavodybynemala presiahnu 50 C Pozn mka Filtra no ventila n jednotky uktor chdo lokp du pr padnekpo kodeniu by nemaliby ponoren vzh adomkmo n muvniknutiuvody Bat riana istenie...

Page 52: ...ovania UR ENIECHYBY Slab bat ria LED erven Slab prietok Symbol Popis Zamedzte vystaveniuoh u skladovaniumimoodpor an horozsahutepl t Rozpoznani ez pachu Slab prietok ajbat ria iadny pr vod vzduchua ia...

Page 53: ...aprepre ujevdorumazanijeinsmeti Preglejtefilterinnotranjetesnilopredprvonamestitvijoaliponovnonamestitvijointakoj zamenjajte esopo kodovani Podrobnopreglejteplasti noohi jefiltra vklju noskotiinzapahi...

Page 54: ...turavodenesmepresegati50 C Opomba Napraveturbozatla nofiltracijozraka kisopadlealisepo kodovalenesmejobiti potopljenealivstavljenev istilnikrespiratorjevzaradimorebitnegavdoravode Baterijeje mogo epot...

Page 55: ...opolnjenje Minimalnotrajanjebaterije ure Zaslon Merilec Vibrator Komentarji Opozorila ODKRIVANJENAPAK Slaba baterija LED rde a Slabtok Simbol Definicija Ne izpostavljajteognju shranjujtezunajpriporo e...

Page 56: ...09 9615000 91 3M 3M 3M Versa o TR 602E EN12941 TR 630 TR 632 TR 602E IDLH 3M 19 5 a b c d e f 3M 3M 3M TR 602E 3M 1 100 80 5 20 1 2 3 TR 602E 3M 3M 4 A5 1 4 4 3 2 C5 B5 6 1 6 7 MMDF 3M 1 2 3M 3M 3 9 8...

Page 57: ...5 3 54 54 C60 1 2 2 3 16 17 4 18 19 30 C50 20 A21 B21 _ _ _ 80 x1 x2 x3 1 2 3 4 54 5 1 2 3 4 1 2 3 3M 0 40 3M 30 50 250 80 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 56...

Page 58: ...min170 MMDF 190 205 220 3050 100 AhLiion2 5 1 11 8 7AhLiion 1 11 20 C 5 3 5 4 54 54 10 TR 602E 1120g IP 4 IP54 5 1 7 6 IP67 EEC 89 686 CE 11 10 BSI KitemarkCourt DavyAvenue 0086 Knowlhill MiltonKeyne...

Page 59: ...eid Kahjustusekorral koheseltv ljavahetada Kuifiltritonvalestik sitletudv iseeonmahakukkunud tehap hjalikkontroll KuiTeilon mingeidk simusi v tke hendust3Mtehnilisetoega Paigaldagefilterpuhurilealati...

Page 60: ...b paigaldagapuhastusjahoiustamisepistikud vtjoonist19 Pistikuteltuleksennekasutamist kontrollidakahjustusijakulumist L bikulunudv ikahjustunudtihendidtulebasendada Pistikuidtuleksasendadapealeiga30kas...

Page 61: ...alid Vibratsioon Kommentaarid Hoiatused RIKKEOTSING Akuon t hi LED pinane V hene huvoog S mbol M ratlus V ltige kokkupuudettulega hoiustamistv ljaspoolsoovitatavattemperatuurivahemikku L hna ilmnemine...

Page 62: ...sapstiprin tufiltru 3Mapstiprin tofiltrusarakstu l dzam skat tTR 602Emotoriz t s gaisapadevesier cesinformat vaj lap Iek j aizdareirgalven aizdarestarpfiltruun Motoriz togaisapadevesier ci r j barjera...

Page 63: ...avaiieliktarespiratoramazg t j joiesp jama densiek ana Ar akumulatorsvar tiktiem rkts laitoizt r tu AtvienojietakumulatorunoMotoriz t sgaisapadevesier cesun izmantojiett r anassegumu pieejamsk papildi...

Page 64: ...perat rair p rsniegusi54 Cdarb bastemperat ru P rvietotuzv s kuvietu 5 Net rumiuzakumulatorakontaktiem P rliecinieties kaakumulatorakontaktiir t ri 1 Noblo ta tene Izt riet nomainiet teni 2 Nosegts lt...

Page 65: ...istarpiklistarpfiltroirorofiltravimo renginio I orinisu kardasapsaugonuone varum iratliek patekimo Patikrinkitefiltr irvidin tarpikl prie montuodamipirm kart arba d damipakartotinai ir nedelsiantj pak...

Page 66: ...aba nukritusioarbapa eistoorofiltravimo renginionegalimanardintiarbad ti respiratori plautuv nes j galipatektivandens Baterij taippatgalimanardintiplaunant I imkitebaterij i orofiltravimo renginioiru...

Page 67: ...Vir ytabaterijospaketo54 Cveikimo temperat ra I ne kite v sesn viet 5 Ne var sbaterijoskontaktai U tikrinkite kadbaterijoskontaktaib t var s 1 U kim ta arnel I valykite pakeiskite arnel 2 Filtrasu de...

Page 68: ...aprinapasarepeindicator asacumsearatainFig2 1bar maiputinde 20 5bari intre80si100 UnindicatordebateriesegasestepeecranulUnitatiiturbocu presiunepozitiva MontatiacumulatorulasacumsearatainFig3 Blocajul...

Page 69: ...centralaacenturiipestemarginiledeblocaresi lasatisaalunececenturainjos vedetiFig16 4Inlaturatifiltrul dacaestenecesar ApasatipefiltruldeblocaresiscoatetifiltruldinUnitatea turbocupresiunepozitiva vede...

Page 70: ...Curatati inlocuitifurtunul 2 Capacul ltrului Faraobstructii 3 Filtreblocate Inlocuiti ltrelesi pre ltrele 4 Temperaturaadepasitduratade operatiune Indepartatidinlocatia ventilata 1 Contactulbaterieie...

Page 71: ...rsaflo TR 602E 3M Versaflo TR 602E a b c d 3M 3M Versaflo TR 602E EN12941 TR 630 TR 632 TR 602E IDLH 19 5 3 a b c d e f 3M 3 3M 3M TR 602E 1 2 1 20 5 80 100 3 3M TR 602E 3 4 4 5A 1 2 3 4 5B 5C 6 1 6 7...

Page 72: ..._ _ _ _ _ 80 1 2 3 1 3M 2 3 3 4 8 4 9 10 11 12 13 4 5 1 14 15 1 30 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 5 54 C 54 C 60 C 1 2 2 3 16 4 17 18 19 71...

Page 73: ...10 15 60 C 30 C 50 C 90 4 C 35 C 5 5 15 C 12 TR 602E EN12941 TR 602E LYYDDD B14112 B 2014 112 EN12941 EN12942 1 2 3 4 54 C 5 1 2 3 4 1 2 3 3 _ _ _ _ 30 50 C 20 21A 21B 0 40 C 3 30 50 250 80 72...

Page 74: ...205 220 100 3050 11 1 5 2 11 1 7 8 6 12 9 5 19 10 12 15 19 5 5 11 5 8 5 15 9 5 11 5 14 5 15 4 5 9 5 7 14 5 8 5 9 5 13 5 14 5 P P P 20 C 3 5 4 5 10 C 54 C 54 C TR 602E 1120g IP IP54 5 4 IP67 6 7 1 89...

Page 75: ...Versaflo TR 602E a b c d 3 03680 12 044 4905777 044 4905775 3M Versaflo TR 602E EN12941 2004 TR 630 TR 632 TR 602E 19 5 3M a b c d e f 3 3 3M TR 602E 1 2 1 20 5 80 100 3 3M TR 602E 3 4 4 5A 1 2 3 4 5B...

Page 76: ..._ _ _ _ _ 80 1 2 3 3 3 8 9 10 11 12 13 4 5 1 14 15 1 30 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 5 Note 54 C 54 C 60 1 2 2 3 16 4 17 18 19 30 50 20 2 21A 21B 75...

Page 77: ...100 3050 1 2 3 4 54 C 5 1 2 3 4 1 2 3 3 11 1 5 2Li ion 11 1 7 8Li ion 6 12 9 5 19 10 12 15 19 5 5 11 5 8 5 15 9 5 11 5 14 5 15 4 5 9 5 7 14 5 8 5 9 5 13 5 14 5 _ _ _ _ 3M 0 40 C 3 30 50 250 80 20 C 3...

Page 78: ...etkusnapomenamazaTR 602E PoweredAirTurbojedinicupopisfilteraodobrenihodtvrtke3M Unutarnjizatvara jeprimarni zatvara izme ufilteraiPoweredAirTurbojedinice Vanjskapregradaspre avaulazprljav tinei krhoti...

Page 79: ...ti zamijenjenisvakih30upotreba ilinagodi njojrazini todo eprije Temperaturavodenesmije prelaziti50stupnjevaCelzijusa Napomena PoweredAirTurbojedinicakojajepalailiseo tetila nebismjelabitiumo enau vodu...

Page 80: ...nakutija Vibriranje Komentari upozorenja TRA ENJEGRE KE Slaba baterija LED crveno Slab protok Simbol Definicija Ne Izlagativatri uvatiizvanpreporu enihrasponatemperature Otkriveni miris Slabprotoki ba...

Page 81: ...Versaflo TR 602E a b c d 3 3 4 2 1766 02 9601911 3M Versaflo TR 602E EN12941 TR 632 TR 630 TR 602E 19 5 3M a b c d e f a 3 3 3 TR 602E 3M 1 2 1 20 5 80 100 3 TR 602E 3M 3 4 4 5A 1 2 3 4 5B 5C 6 1 6 7...

Page 82: ..._ _ _ _ _ LED LED LED LED LED LED 80 1 2 3 9 10 11 12 13 4 5 1 14 15 1 30 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 5 54 C 54 C 60 1 2 2 3 16 4 17 18 19 30 50 20 21A 21B 81...

Page 83: ...V 52 11 1 V7 8 LED LED LED 1 2 3 4 54 C 5 1 2 3 4 1 2 3 3 20 C 3 5 4 5 10 C 54 C 54 C TR 602E 1120g IP IP545 4 IP67 6 7 1 89 686 EEC 10 11 BSIProductServices KitemarkCourt Davy Avenue Knowlhill Milton...

Page 84: ...einstalacijeilireinstalacijeiodmahzamenite akojeo te en Pa ljivoproveriteplasti nidr a filterauklju uju iugloveireze Odmahzameniteakoje o te eno Akonijedobrorukovanosafilteromilivamjeispaopotrebnojedo...

Page 85: ...orajubitiuba eneuPoweredAir Turboprvo Slika19 Uti nicetrebaproveritiodo te enjaihabanjapresvakeupotrebe Pohabanilio te enpri vr iva moradasezameni Uti nicetrebazamenitinakonsvake30 upotrebeiligodi nje...

Page 86: ...rveno Nizak protok Simbol Definicija Nemojte Izlagativatri Skladi titivanpreporu enogopsegatemperature Detektovan miris Nizakprotoki prazna baterija Nemani protokani alarma Sistemski alarm Led crveno...

Page 87: ...luHava Sistemiaras ndakibirincils zd rmazl kunsurudur D bariyer kirveart klar ni erigirmesini nler lktakmaveyatekrartakmai lemindensonrafiltreyivei koruyucuyuinceleyinvehasarl isede i tirin Filtreninm...

Page 88: ...hery lde i tirilmelidir Sus cakl 50 C yia mamal d r Not Yered enveyahasarl sistemler olas sus z nt lar nakar suyadald r lmamal veya maskey kamamakinesindetemizlenmemelidir Bataryadatemizlemeama l olar...

Page 89: ...k rm z D k Ak Sembol A klama Bunlar yapmay n z Ate emaruzb rakmay n z nerilens cakl karal n nd ndamuhafazaetmeyiniz Alg lanan Koku D kAk vePil Ak Yok AlarmYok Sistem Alarm LED k rm z LEDler k rm z Yu...

Page 90: ...oweredAirTurbo TR 602EPoweredAirTurbo 19 5 3 a E b c d e f 3 AirTurbo 3M 3 3M TR 602EPoweredAir Turbo 1 2 1 20 5 80 100 PoweredAirTurbo 3 3M TR 602EPoweredAirTurbo Powered AirTurbo 3M PoweredAirTurbo...

Page 91: ...irTurbo 18 PoweredAirTurbo PoweredAir Turbo PoweredAir Turbo PoweredAirTurbo 19 30 50 C PoweredAirTurbos PoweredAirTurbo 20 21A 21B 80 x1 x2 x3 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 3M PoweredAirTurbo 8 9...

Page 92: ...09 10 1 2009 10 1 EN12941 Headtop MMDF 170 190 205 220 100 3050 11 1 5 2 11 1 7 8 1 2 3 4 54 C 5 1 2 3 4 1 2 PoweredAirTurbo 3 PoweredAirTurbo 3M 20 C 3 5 4 5 10 C 54 C 54 C TR 602E 1120g IP IP54 5 4...

Page 93: ...plastichousingincludingthecornersandlatches Immediatelyreplaceif damaged Ifthefilterhasbeenmishandledordropped re inspectfully Ifyouhaveanyconcern contact 3MTechnicalServiceforguidance Alwaysproperlyi...

Page 94: ...dandtheairinletandairoutletcleaningandstorageplugsmustbe insertedintothePoweredAirTurbofirst seeFig19 Plugsshouldbeinspectedfordamageand wearpriortoeachuse Wornordamagedsealsmustbereplaced Plugsshould...

Page 95: ...s Display Sounder Vibrate Comments Warnings FAULTFINDING Low Battery LED red LowFlow Symbol Definition Donot Exposetofire Storeoutsideofrecommendedtemperaturerange Odour Detected LowFlow andBattery No...

Page 96: ...Portugal Lda Rua do Conde de Redondo 98 1169 009 Lisboa 351 21 313 45 00 3M Poland Sp z o o Aleja Katowicka 117 Kajetany K Warszawy 05 830 Nadarzyn 48 22 739 60 00 3M Hung ria Kft Inforpark E p let 11...

Page 97: ......

Reviews: