NOTE: If the print pad is out of range, you will need to perform a
manual adjustment .
4 . Remove the print pad and select the
checkmark
to continue .
NOTE: To remove it, lift up the front of the print pad and pull it out of
the printer . The print pad is magnetically attached to the adjustment
knobs .
5 . When prompted, loosen the lock screw that is indicated on the touchscreen
display . Select the
checkmark
to continue .
NOTE: Use a 1 .5 mm Allen wrench that is included with the printer .
NOTE: The lock screw (1) is located just below the adjustment knob
(2) . The lock screw for adjustment knob B can be accessed from the
front of the printer . The lock screw for adjustment knob A can be
accessed from behind the printer .
6 . Follow the instructions on the touchscreen display . Once the adjustments have
been made, select the
checkmark
to continue .
7 . When prompted, tighten the lock screw enough to ensure the adjustment knob
does not easily turn . Select the
checkmark
to continue .
Caution: Do not over-tighten the lock screw . This can damage the
adjustment knob and void the manufacturer’s warranty.