18-3
IM 05P02C41-01EN
Parameters
18
The parameters in the menu of the following table indicate the parameters to set the
basic functions of the controller. The symbol in parentheses are shown on Group display.
Menu symbol
Functions
PASS
Password setting (Displayed only when the password has been sent.)
Menu symbol
Functions
CTL
Control mode, control type, sampling period, segment setting method, program time unit, etc
PV
PV input type, range, scale, etc
RSP
RSP remote input type, scale, etc
AIN2
AIN2 aux. analog input type, scale, etc
AIN4
AIN4 aux. analog input type, scale, etc
MPV
Input function in Loop control with PV switching and Loop control with PV auto-selector, SP limiters,
etc.
MPV (LP2)
Loop-2 input function, SP limiters (Loop 2), etc in Cascade control.
OUT
Control output type, valve position adjustment, retransmission output, etc.
HBA
Heater break alarm
R485 (E3)
RS-485 communication (E3-terminal area)
R485 (E4)
RS-485 communication (E4-terminal area)
ETHR (E3)
Ethernet communication, gateway setting, IP access restriction, etc. (E3-terminal area)
PROF (E3)
PROFIBUS-DP communication (E3-terminal area)
DNET (E3)
DeviceNet communication (E3-terminal area)
CC-L (E3)
CC-Link communication (E3-terminal area)
KEY
Function of User function key
DISP
Display functions
CSEL
SELECT Display, SELECT parameter registration
KLOC
Key lock
MLOC
Parameter menu lock
DI.SL
Contact input function
DI.NU
Contact input function (bit selection)
DI.D
Contact input type (equipped as standard)
DI.D (E1)
Contact input type (E1-terminal area)
DI.D (E2)
Contact input type (E2-terminal area)
DI.D (E3)
Contact input type (E3-terminal area)
DI.D (E4)
Contact input type (E4-terminal area)
ALM
Alarm output function, contact output type (equipped as standard)
DO (E1)
Contact output function, contact output type (E1-terminal area)
DO (E2)
Contact output function, contact output type (E2-terminal area)
DO (E3)
Contact output function, contact output type (E3-terminal area)
DO (E4)
Contact output function, contact output type (E4-terminal area)
I/O
Input / output data display
SYS
Action setting when recovering from a power failure, guide display language, password setting, etc
INIT
Initialization of parameter
VER
Error status, version, MAC address, etc
LVL
Parameter display level
Note
Some parameters are not displayed according to the setting such as control mode, control type,
or input and output.
18.1 Parameter Map
Содержание UTAdvanced UP55A
Страница 3: ......
Страница 21: ...Blank Page ...
Страница 37: ...Blank Page ...
Страница 47: ...Blank Page ...
Страница 125: ...Blank Page ...
Страница 147: ...Blank Page ...
Страница 155: ...8 8 IM 05P02C41 01EN Intentionally blank 8 1 Setting Control Mode CTLM ...
Страница 159: ...8 12 IM 05P02C41 01EN Intentionally blank 8 1 Setting Control Mode CTLM ...
Страница 167: ...8 20 IM 05P02C41 01EN Intentionally blank 8 1 Setting Control Mode CTLM ...
Страница 175: ...8 28 IM 05P02C41 01EN Intentionally blank 8 1 Setting Control Mode CTLM ...
Страница 221: ...Blank Page ...
Страница 275: ...Blank Page ...
Страница 351: ...Blank Page ...
Страница 381: ...Blank Page ...
Страница 403: ...Blank Page ...
Страница 491: ...Blank Page ...
Страница 505: ......
Страница 513: ...Blank Page ...
Страница 515: ...Blank Page ...