15.3 Warning Displays
15.3.3 INDEXER Module Error Displays and Troubleshooting
15-61
15
Maintenance
15.3.3
INDEXER Module Error Displays and Troubleshooting
Negative responses (error responses) to input signals, serial commands, or operations from the
Digital Operator are known as errors.
The servo will not be turned OFF when an error occurs.
Status Displays
The INDEXER Module error displays and the corrective actions are shown below.
SERVOPACK Panel Display
“A.A9F” is displayed for 2 seconds.
Indicator
Red indicator: Flashes for 2 seconds.
Refer to the following section for details.
Digital Operator
“A.A9F” is displayed for 2 seconds at the top left of the
screen.
Response to the Alarm or Warning Read
Command (ALM)
No change
Response to the Most Recent Error Read
Command (ERR)
Error code (the most recent (closest) error code)
ALM Signal
No change
/WARN Signal
The signal is valid for 2 seconds.
Serial
Command
Negative
Response
Alarm
Number
Error Name
Meaning
Corrective Action
E41E
A.A9F
Program Table
Save Failure Error
While writing data to the flash memory, a
failure occurred during one of the following
operation.
•
While saving a program table by using a
PGMSTORE command
•
While saving a program table by using
FnB03
•
While initializing a program table by using
a PGMINIT command
•
While initializing a program table by using
FnB06
Repair the hard-
ware.
E42E
A.A9F
ZONE Table Save
Failure Error
While writing data to the flash memory, a
failure occurred during one of the following
operation.
•
While saving a ZONE table by using a
ZONESTORE command
•
While saving a ZONE table by using
FnB04
•
While initializing a ZONE table by using a
ZONEINIT command
•
While initializing a ZONE table by using
FnB07
Repair the hard-
ware.
Continued on next page.