8.14 Diagnostic Tools
8.14.2 Easy FFT
8-93
8
T
uning
7.
Click the
Result Writing
Button if you want to set the measurement results in the param-
eters.
This concludes the procedure to set up Easy FFT.
Related Parameters
The following parameters are automatically adjusted or used as reference when you execute
Easy FFT.
Do not change the settings of these parameters during execution of Easy FFT.
Yes: The parameter is automatically set.
No: The parameter is not automatically set, but the setting is read during execution.
Parameter
Name
Automatic Changes
Pn408
Torque-Related Function Selections
Yes
Pn409
First Stage Notch Filter Frequency
Yes
Pn40A
First Stage Notch Filter Q Value
No
Pn40C
Second Stage Notch Filter Frequency
Yes
Pn40D
Second Stage Notch Filter Q Value
No
Pn456
Sweep Torque Reference Amplitude
No