6.1 I/O Signals
6.1.1 Input Signals
6-5
6
Application Functions
You can change the setting for the /START-STOP signal with PnB04. If you change the setting
for the /START-STOP signal, set the /MODE 0/1 signal to ON (closed) (Mode 0).
/HOME (Homing Input) Signal
This signal functions as the homing command.
You can change the setting for the /HOME signal with PnB04. If you change the setting for the
/HOME signal, set the /MODE 0/1 signal to OFF (open) (Mode 1).
/PGMRES (Program Table Operation Reset Input) Signal
If this signal turns ON while a program table operation is stopped, the program table operation
will be reset and canceled.
*
*
“Canceled” is the state in which the mode is mode 0, execution is not in a stopped state, and no program step
has been executed.
You can change the setting for the /PGMRES signal with PnB05. If you change the setting for
the /PGMRES signal, set the /MODE 0/1 signal to ON (closed) (Mode 0).
Parameter
Meaning
When Enabled
Classification
PnB04
0000h
(default setting)
Starts program table operation when the
/START-STOP signal turns ON (closes). Stops
program table operation when the /START-STOP
signal turns OFF (opens).
After restart
Setup
0001h
Starts program table operation when the
/START-STOP signal turns OFF (opens). Stops
program table operation when the /START-STOP
signal turns ON (closes).
0002h,
0003h
The /START-STOP signal is not used.
Type
Signal
Pin No.
Signal Status
Meaning
Input
/HOME
CN11-5
ON (closed)
Homing is started.
OFF (open)
Stops homing.
Parameter
Meaning
When Enabled
Classification
PnB04
0000h
(default setting)
Starts homing when the /HOME signal turns ON
(closes).
After restart
Setup
0001h
Starts homing when the /HOME signal turns OFF
(opens).
0002h,
0003h
The /HOME signal is not used.
Type
Signal
Pin No.
Signal Status
Meaning
Input
/PGMRES CN11-7
ON (closed)
Program table operation is reset.
OFF (open)
Program table operation is not reset.
Parameter
Meaning
When Enabled
Classification
PnB05
0000h
(default setting)
Resets and cancels program table operation by
switching the /PGMRES signal from OFF (open)
to ON (closed).
After restart
Setup
0001h
Resets and cancels program table operation by
switching the /PGMRES signal from ON (closed)
to OFF (open).
0002h,
0003h
Program table operation is not reset.