Pn163
2
Anti-Resonance Damp-
ing Gain
0 to 300
1%
0
All
Immedi-
ately
Tuning
Pn164
2
Anti-Resonance Filter
Time Constant 1 Cor-
rection
-1,000 to
1,000
0.01 ms
0
All
Immedi-
ately
Tuning
Pn165
2
Anti-Resonance Filter
Time Constant 2 Cor-
rection
-1,000 to
1,000
0.01 ms
0
All
Immedi-
ately
Tuning
Pn166
2
Anti-Resonance Damp-
ing Gain 2
0 to 1,000
1%
0
All
Immedi-
ately
Tuning
Pn170
2
Tuning-less Function-
Related Selections
0000h to
2711h
–
1401h
All
–
Setup
Pn181
2
Mode Switching Level
for Speed Reference
0 to 10,000
1 mm/s
0
Linear
Immedi-
ately
Tuning
Pn182
2
Mode Switching Level
for Acceleration
0 to 30,000
1 mm/s
2
0
Linear
Immedi-
ately
Tuning
Pn205
2
Multiturn Limit
0 to 65,535
1 rev
65535
*2
Rotary
After
restart
Setup
Pn207
2
Reserved parameter
(Do not change.)
–
–
0010h
*1
All
–
–
–
Pn20A
4
Number of External
Encoder Scale Pitches
4 to
1,048,576
1 scale
pitch/
revolu-
tion
32768
Rotary
After
restart
Setup
Pn20E
4
Electronic Gear Ratio
(Numerator)
1 to
1,073,741,824
1
64
All
After
restart
Setup
Pn210
4
Electronic Gear Ratio
(Denominator)
1 to
1,073,741,824
1
1
All
After
restart
Setup
Pn212
4
Number of Encoder
Output Pulses
16 to
1,073,741,824
1 P/Rev
2048
Rotary
After
restart
Setup
Pn217
2
Average Movement
Time of Position Refer-
ence
0 to 10,000
0.1 ms
0
All
After the
change
and also
after the
motor has
stopped
Setup
–
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Tuning-less Selection
When
Enabled
0
Disable tuning-less function.
After
restart
1
Enable tuning-less function.
n.
X
Reserved parameter (Do not change.)
n.
X
Rigidity Level
When
Enabled
0 to 7
Set the rigidity level.
Immedi-
ately
n.X
Tuning-less Load Level
When
Enabled
0 to 2
Set the load level for the tuning-less function.
Immedi-