5.1 Manipulating Parameters (Pn
)
5.1.5 Initializing Parameter Settings
5-10
5.1.5
Initializing Parameter Settings
You can return the parameters to their default settings. This function restores the factory set-
tings and initializes the parameters of both the SERVOPACK and the INDEXER Module.
This function will not initialize the settings of the parameters that are adjusted for the Fn00C,
Fn00D, Fn00E, and Fn00F utility functions.
Preparations
Always check the following before you initialize the parameter settings.
•
The parameters must not be write prohibited.
•
The servo must be OFF.
•
Initializing the parameter settings must not be in progress for any other tool.
•
Execution of the RES command must not be in progress.
Applicable Tools
The following table lists the tools that you can use to initialize the parameter settings and the
applicable tool functions.
Operating Procedure
Use the following procedure to initialize the parameter settings.
1.
Click the
Servo Drive Button in the workspace of the Main Window of the Sig-
maWin+.
2.
Select
Edit Parameters
in the Menu Dialog Box.
The Parameter Editing Dialog Box will be displayed.
3.
Select any parameter of the axis to initialize.
•
To bring the settings into effect, always turn the SERVOPACK power supply off and back on
after this operation.
•
The parameters of the INDEXER Module are not initialized with Fn005. To initialize these
parameters, execute FnB0B.
Tool
Function
Reference
Digital Operator
FnB0B
Σ
-7-Series Digital Operator Operating
Manual (Manual No.: SIEP S800001
33)
S
Parameters - Edit Parameters
Serial command com-
munications
PRMINIT (Parameter Initialization) com-
mand
Important