15.3 Warning Displays
15.3.3 INDEXER Module Error Displays and Troubleshooting
15-67
15
Maintenance
E58E
A.A9F
Data Out-of-
range Error
The specified setting was incorrect in a
parameter or program table write com-
mand.
Check the set-
ting.
E59E
A.A9F
Communication
Failure Error
between
INDEXER Module
and SERVOPACK
Communications between the INDEXER
Module and the SERVOPACK have failed.
Check the ver-
sion of the SER-
VOPACK.
E5AE
A.A9F
Execution Dis-
abled while Servo
ON Error
Some of the utility functions, such as
parameter initialization, has been requested
while still in the servo ON status. For safety,
the following functions cannot be executed
in the servo ON status.
•
Serial commands: Parameter initializa-
tion, absolute encoder
reset, motor current
zero adjustment
•
S: Parameter initialization
Execute these
functions after
turning the servo
OFF.
E5BE
A.A9F
Execution Dis-
abled while Alarm
Activated Error
Servo ON was requested (the SVON com-
mand was executed) while there was an
alarm.
Turn the servo
ON after eliminat-
ing the cause of
the alarm and
clearing the
alarm.
E5CE
A.A9F
Execution Dis-
abled while Main
Power OFF Error
Servo ON was requested (the SVON com-
mand was executed) while the main power
supply was OFF.
Turn the servo
ON after turning
ON the main
power supply.
E5DE
A.A9F
Homing Method
Unspecified Error
The homing method is not specified.
•
Homing start was requested (/HOME sig-
nal was turned ON or ZRN command was
executed) without setting the homing
method.
Specify the hom-
ing method in
PnB31.
E5EE
A.A9F
Execution Dis-
abled during Pro-
gram Table
Operation Error
•
There was a request to execute a process
that is not allowed during program table
operation while program table operation
was in progress or on hold.
•
There was an attempt to change the pro-
gram table while program table operation
was in progress or on hold.
•
There was a request to start positioning
by a serial command while program table
operation was in progress or on hold.
Request execu-
tion of the pro-
cess again after
canceling pro-
gram table oper-
ation by turning
the
/PGMRES signal
ON.
E5FE
A.A9F
Session Conflict
Error
There was a request that could not be exe-
cuted at the same time as the function that
was being executed.
Example:
There was a request to start program table
operation while the program table was
being initialized.
Execute the
operation again
after the execu-
tion of the current
function is com-
pleted.
Continued on next page.
Continued from previous page.
Serial
Command
Negative
Response
Alarm
Number
Error Name
Meaning
Corrective Action