2.1 Ratings and Specifications
2.1.1 Ratings
2-2
2.1
Ratings and Specifications
This section gives the ratings and specifications of SERVOPACKs.
2.1.1
Ratings
Three-Phase, 200 VAC
*
This is the net value at the rated load.
Model SGD7S-
R70A R90A 1R6A 2R8A 3R8A 5R5A 7R6A 120A
180A
200A
330A
Maximum Applicable Motor
Capacity [kW]
0.05
0.1
0.2
0.4
0.5
0.75
1.0 1.5 2.0 3.0 5.0
Continuous Output
Current [Arms]
0.66 0.91 1.6
2.8
3.8
5.5
7.6
11.6
18.5
19.6
32.9
Instantaneous Maximum
Output Current [Arms]
2.1
3.2
5.9
9.3
11
16.9
17
28
42
56
84
Main
Circuit
Power Supply
200 VAC to 240 VAC, -15% to +10%, 50 Hz/60 Hz
Input Current
[Arms]
*
0.4
0.8
1.3
2.5
3.0
4.1
5.7
7.3
10
15
25
Con-
trol
Power Supply
200 VAC to 240 VAC, -15% to +10%, 50 Hz/60 Hz
Input Current
[Arms]
*
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.25
0.25
0.3
Power Supply Capacity
[kVA]
*
0.2
0.3
0.5
1.0
1.3
1.6
2.3
3.2
4.0
5.9
7.5
Power
Loss
*
Main Circuit Power
Loss [W]
5.0
7.0
11.9
22.5
28.5
38.9
49.2
72.6
104.2 114.2 226.6
Control Circuit
Power Loss [W]
12
12
12
12
14
14
14
15
16
16
19
Built-in Regenera-
tive Resistor Power
Loss [W]
−
−
−
−
8
8
8
10
16
16
36
Total Power Loss
[W]
17.0
19.0
23.9
34.5
50.5
60.9
71.2
97.6
136.2 146.2 281.6
Rege
nera-
tive
Resis-
tor
Built-In
Regen-
erative
Resis-
tor
Resis-
tance [
Ω
]
−
−
−
−
40
40
40
20
12
12
8
Capacity
[W]
−
−
−
−
40
40
40
60
60
60
180
Minimum Allowable
External Resis-
tance [
Ω
]
40
40
40
40
40
40
40
20
12
12
8
Overvoltage Category
III