8.13 Manual Tuning
8.13.2 Compatible Adjustment Functions
8-85
8
T
uning
Related Parameters
Select the switching condition for mode switching with Pn10B = n.
X.
Parameters That Set the Switching Levels
•
Rotary Servomotors
•
Linear Servomotors
Parameter
Mode Switching
Selection
Parameter That Sets the
Level
When
Enabled
Classification
Rotary
Servomotor
Linear
Servomotor
Pn10B
n.
0
(default setting)
Use the internal
torque reference as
the condition.
Pn10C
Immediately
Setup
n.
1
Use the speed ref-
erence as the con-
dition.
Pn10D
Pn181
n.
2
Use the accelera-
tion reference as
the condition.
Pn10E
Pn182
n.
3
Use the position
deviation as the
condition.
Pn10F
n.
4
Do not use mode
switching.
−
Pn10C
Mode Switching Level for Torque Reference
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 800
1%
200
Immediately
Tuning
Pn10D
Mode Switching Level for Speed Reference
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 10,000
1 min
-1
0
Immediately
Tuning
Pn10E
Mode Switching Level for Acceleration
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 30,000
1 min
-1
/s
0
Immediately
Tuning
Pn10F
Mode Switching Level for Position Deviation
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 10,000
1 reference unit
0
Immediately
Tuning
Pn10C
Mode Switching Level for Force Reference
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 800
1%
200
Immediately
Tuning
Pn181
Mode Switching Level for Speed Reference
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 10,000
1 mm/s
0
Immediately
Tuning
Pn182
Mode Switching Level for Acceleration
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 30,000
1 mm/s
2
0
Immediately
Tuning
Pn10F
Mode Switching Level for Position Deviation
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 10,000
1 reference unit
0
Immediately
Tuning