26
2.
For the Installer
2.4.10 Wood gasification boiler: Mount shaft for heating surface cleaning
lever
Note!
The heating surface cleaning lever can only be mounted on the left-hand side of the boiler.
Initially, install only the shaft and the short lever; the side panel has to be mounted first and then
the complete cleaning lever can be assembled (section 2.4.20).
– Connect both shaft components (Fig. 34) and push the pointed side of the shaft into the rod axle – Fig. 35.
– Screw the shorter lever to the shaft using a hexagon screw M8x16 and a U-washer 8 – Fig. 36.
Fig. 34 Connect both parts of the shaft
Fig. 35 Push the shaft into the rod axle
Fig. 36 Screw the shorter lever into
position