2.
For the Installer
2.4.17 Wood gasification boiler: rear panel insulation installation
– Install insulation on top and bottom as shown in Fig.58.
Fig. 55 Installing insulation on the rear panel
Fig. 56 If no adapter is being used for the flue
connection, remove the cut-out
2.4.18 Wood gasification boiler: rear panels installation
– If no adapter for the flue gas blower (accessories) is being used, remove the cut-out at the top of the back
panel – Fig. 59.
large cut-out = exhaust pipe insulated
small cut-out = exhaust pipe not insulated
do not remove = adapter for flue connection installed
– Fasten the rear panel with 4 screws at the top and 4 screws at the bottom – Fig. 60.
– Connect the blower plug to the flue gas blower. Secure cable at side with cable ties – Fig. 60.
Fig. 57 Fitting the rear panels
4 each of
4 each of
Blower plugs