6.4 Pellet boiler connection diagram changeover unit
Two separate cables are needed to connect the changeover unit.
– Cable for limit switch (extra-low voltage): min. 3 x 0.5 mm
2
(no ground); we recommend using a shielded cable if the cable is longer than 5 m.
– Cable for changeover unit motor (low voltage): 4 x 1.5 mm