background image

   

The Vollrath Company, L.L.C. 

 

1236 North 18

th

 Street 

 

P.O. Box 611 

 

Sheboygan, WI  53082-061  

 

 

 
 
 

 

 

Operating and Safety 
Instructions 

Gas Hot Plates 

 

Model Number: 

40736, 12” 52,000 BTU/hr - Natural Gas* 
40737, 24” 104,000 BTU/hr – Natural Gas* 
40738, 36” 156,000 BTU/hr – Natural Gas* 
 
*Includes kit for conversion to Propane Gas.  

 

IMPORTANT:

 It is vital that the purchaser of this equipment post in a 

prominent location instructions to be followed in the event that the user 
smells gas. This information shall be obtained by consulting the local gas 
supplier.  

 

Содержание Cayenne 40737

Страница 1: ...00 BTU hr Natural Gas 40737 24 104 000 BTU hr Natural Gas 40738 36 156 000 BTU hr Natural Gas Includes kit for conversion to Propane Gas IMPORTANT It is vital that the purchaser of this equipment post in a prominent location instructions to be followed in the event that the user smells gas This information shall be obtained by consulting the local gas supplier ...

Страница 2: ...ce risk of injury or death Do not store flammable liquids near this unit Unit should only be used in a flat level position Let hot unit cool before cleaning or moving Do not spray controls or outside of unit with liquids or cleaning agents Do not operate unattended WARNING Have this equipment installed by a qualified installer in accordance with all federal state and local codes Failure to install...

Страница 3: ...e gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psi 3 5 kPa Orifice sizing Equipment is manufactured for 1000 BTU per cubic...

Страница 4: ...re regulator Gas piping Gas Piping shall be of such size and so installed as to provide a supply of gas sufficient to meet the full gas input of the appliance If the appliance is to be connected to existing piping it shall be checked to determine if it has adequate capacity Joint compound pipe dope shall be used sparingly and only on the male threads of the pipe joints Such compounds must be resis...

Страница 5: ...h any open flames Immediately call your gas supplier WARNING FIRE INJURY OR DEATH HAZARD Have this equipment installed and adjusted by a qualified technician in accordance with all federal state and local codes Failure to install adjust or maintain this equipment properly can result in injury or death PILOT FLAME REGULATION The pilot flame on the appliance has been factory adjusted Whenadjustment ...

Страница 6: ...ting the Authorized Professional Service Center please be ready with the item number model number if applicable serial number and proof of purchase showing the date the unit was purchased Warranty Statement for The Vollrath Co L L C This warranty does not apply to products purchased for personal family or household use and The Vollrath Company LLC does not offer a written warranty to purchasers fo...

Отзывы: