9-5
9
Scalar Control (V/f)
P0140 – Dwell Time at Start
Adjustable
Range:
0.0 to 10.0 s
Factory
Setting:
0.0 s
P0141 – Dwell Speed at Start
Adjustable
Range:
0 to 300 rpm
Factory
Setting:
90 rpm
Properties:
V/f and VVW
Access groups
via HMI:
01 PARAMETER GROUPS
23 V/f Control
Description:
P0140 sets the time during which the speed is kept constant during the acceleration. Refer to the
P0141 sets the speed step during the acceleration. Refer to the
.
By means of these parameters it is possible to introduce a speed step during the acceleration, helping the starting of
high torque loads.
Speed
Time
P0140
P0141
Figure 9.7 -
Acceleration speed profile as a function of P0140 and P0141
NOTE!
The accommodation time will be considered null when the Flying Start function is active
(P0320 = 1 or 2).
P0202 – Type of Control
Adjustable
Range:
0=V/f 60 Hz
1=V/f 50 Hz
2=V/f Adjustable
3=Sensorless
4=Encoder
5=VVW (Voltage Vector WEG)
6=Encoder PM
7=Sensorless PM
Factory
Setting:
0
Properties:
CFG
Access groups
via HMI:
01 PARAMETER GROUPS
23 V/f Control
Содержание CFW-11 Series
Страница 2: ......
Страница 54: ...2 4 2 General Information ...
Страница 58: ...About the CFW 11 3 3 4 ...
Страница 74: ...Inverter Model and Accessories Identification 5 14 6 ...
Страница 86: ...Inverter Model and Accessories Identification 6 12 6 ...
Страница 94: ...Available Control Types 8 2 8 ...
Страница 118: ...VVW Control 10 8 10 ...
Страница 182: ...Functions Common to All the Control Modes 12 26 12 ...
Страница 220: ...Dynamic Braking 14 4 14 ...