Quick Parameter Reference, Faults and Alarms
0-34
0
Fault/Alarm
Description
Possible Causes
F183
IGBT Ov
Temperature
Overtemperature related to the IGBTs overload
protection.
Surrounding air temperature too high.
Operation with frequencies < 10 Hz under overload.
F185
(8)
Pre-charge Contac Fault
It indicates fault at the pre-charge Contactor.
Pre-charge contactor defect.
Open command fuse.
Phase loss in the input L1/R or L2/S.
P0355 = 1 (Incorrect setting for models frame E or frame
H supplied by the DC link. For those models, the setting
should be P0355 = 0.
F186
(9)
Sensor 1 Temperature Fault
It indicates a temperature fault at the sensor 1.
Motor high temperature.
F187
(9)
Sensor 2 Temperature Fault
It indicates a temperature fault at the sensor 2.
F188
(9)
Sensor 3 Temperature Fault
It indicates a temperature fault at the sensor 3.
F189
(9)
Sensor 4 Temperature Fault
It indicates a temperature fault at the sensor 4.
F190
(9)
Sensor 5 Temperature Fault
It indicates a temperature fault at the sensor 5.
A191
(9)
Sensor 1 Temperature
Alarm
It indicates a temperature alarm at the sensor 1.
Motor high temperature.
A problem in the wiring connecting the sensor to the IOE
01 (02 or 03).
A192
(9)
Sensor 2 Temperature
Alarm
It indicates a temperature alarm at the sensor 2.
A193
(9)
Sensor 3 Temperature
Alarm
It indicates a temperature alarm at the sensor 3.
A194
(9)
Sensor 4 Temperature
Alarm
It indicates a temperature alarm at the sensor 4.
A195
(9)
Sensor 5 Temperature
Alarm
It indicates a temperature alarm at the sensor 5.
A196
(9)
Sensor 1 Cable Alarm
Sensor 1 cable alarm.
Shorted temperature sensor.
A197
(9)
Sensor 2 Cable Alarm
Sensor 2 cable alarm.
A198
(9)
Sensor 3 Cable Alarm
Sensor 3 cable alarm.
A199
(9)
Sensor 4 Cable Alarm
Sensor 4 cable alarm.
A200
(9)
Sensor 5 Cable Alarm
Sensor 5 cable alarm.
F228
Serial Communication
Timeout
Refer to the RS-232 / RS-485 Serial communication manual.
F229
Anybus Offline
Refer to the Anybus-CC communication manual.
F230
Anybus Access Error
F233
CAN Bus Power Failure
Refer to the CANopen communication manual and/or the DeviceNet communication manual.
F234
Bus Off
F235
CANopen Communication
Error
Refer to the CANopen communication manual.
F236
Master Idle
Refer to the DeviceNet communication manual.
F237
DeviceNet Connect
Timeout
(*)
Temperature > 40 ºC or 45 ºC, depending on the model. Refer to the section 3.1 - Installation Environment, of the CFW-11M user's manual.
Содержание CFW-11 Series
Страница 2: ......
Страница 54: ...2 4 2 General Information ...
Страница 58: ...About the CFW 11 3 3 4 ...
Страница 74: ...Inverter Model and Accessories Identification 5 14 6 ...
Страница 86: ...Inverter Model and Accessories Identification 6 12 6 ...
Страница 94: ...Available Control Types 8 2 8 ...
Страница 118: ...VVW Control 10 8 10 ...
Страница 182: ...Functions Common to All the Control Modes 12 26 12 ...
Страница 220: ...Dynamic Braking 14 4 14 ...