Quick Parameter Reference, Faults and Alarms
0-28
0
Parameter
Function
Adjustable Range
Factory Setting
User
Setting
Properties
Groups
Pag.
P0947
Fault Number
0 to 65535
RO
09, 115
P0963
Profibus Baud Rate
0 = 9.6 kbit/s
1 = 19.2 kbit/s
2 = 93.75 kbit/s
3 = 187.5 kbit/s
4 = 500 kbit/s
5 = Not Detected
6 = 1500 kbit/s
7 = 3000 kbit/s
8 = 6000 kbit/s
9 = 12000 kbit/s
10 = Reserved
11 = 45.45 kbit/s
RO
09, 115
P0964
Drive Unit Ident.
0 to 65535
RO
09, 115
P0965
Profile Ident. Number
0 to 65535
RO
09, 115
P0967
Control Word 1
Bit 0 = ON
Bit 1 = No Coast Stop
Bit 2 = No Quick Stop
Bit 3 = Enable Operation
Bit 4 = Enable Ramp
Generator
Bit 5 = Reserved
Bit 6 = Enable Setpoint
Bit 7 = Fault Acknowledge
Bit 8 = Jog 1
Bit 9 = Reserved
Bit 10 = Control by PLC
Bit 11 ... 15 = Reserved
RO
09, 115
P0968
Status Word 1
Bit 0 = Ready To Swtich
On
Bit 1 = Ready To Operate
Bit 2 = Operation Enabled
Bit 3 = Fault Present
Bit 4 = Coast Stop Not
Active
Bit 5 = Quick Stop Not
Active
Bit 6 = Switching On
Inhibited
Bit 7 = Warning Present
Bit 8 = Reserved
Bit 9 = Control By PLC
Bit 10 ... 15 = Reserved
RO
09, 115
P1000
SoftPLC Status
0 = No Application
1 = Install. App.
2 = Incompat. App.
3 = App. Stopped
4 = App. Running
-
RO
09, 50
P1001
SoftPLC Command
0 = Stop Program
1 = Run Program
2 = Delete Program
0
CFG
50
P1002
Scan Cycle Time
0 to 65535 ms
-
RO
09, 50
P1010
SoftPLC Parameter 1
-32768 to 32767
0
-
50
P1011
SoftPLC Parameter 2
-32768 to 32767
0
-
50
P1012
SoftPLC Parameter 3
-32768 to 32767
0
-
50
P1013
SoftPLC Parameter 4
-32768 to 32767
0
-
50
P1014
SoftPLC Parameter 5
-32768 to 32767
0
-
50
P1015
SoftPLC Parameter 6
-32768 to 32767
0
-
50
P1016
SoftPLC Parameter 7
-32768 to 32767
0
-
50
P1017
SoftPLC Parameter 8
-32768 to 32767
0
-
50
P1018
SoftPLC Parameter 9
-32768 to 32767
0
-
50
P1019
SoftPLC Parameter 10
-32768 to 32767
0
-
50
P1020
SoftPLC Parameter 11
-32768 to 32767
0
-
50
P1021
SoftPLC Parameter 12
-32768 to 32767
0
-
50
P1022
SoftPLC Parameter 13
-32768 to 32767
0
-
50
P1023
SoftPLC Parameter 14
-32768 to 32767
0
-
50
P1024
SoftPLC Parameter 15
-32768 to 32767
0
-
50
P1025
SoftPLC Parameter 16
-32768 to 32767
0
-
50
P1026
SoftPLC Parameter 17
-32768 to 32767
0
-
50
P1027
SoftPLC Parameter 18
-32768 to 32767
0
-
50
Содержание CFW-11 Series
Страница 2: ......
Страница 54: ...2 4 2 General Information ...
Страница 58: ...About the CFW 11 3 3 4 ...
Страница 74: ...Inverter Model and Accessories Identification 5 14 6 ...
Страница 86: ...Inverter Model and Accessories Identification 6 12 6 ...
Страница 94: ...Available Control Types 8 2 8 ...
Страница 118: ...VVW Control 10 8 10 ...
Страница 182: ...Functions Common to All the Control Modes 12 26 12 ...
Страница 220: ...Dynamic Braking 14 4 14 ...