Quick Parameter Reference, Faults and Alarms
0-17
0
Parameter
Function
Adjustable Range
Factory Setting
User
Setting
Properties
Groups
Pag.
61 = 8.5 A / 7 A
62 = 10 A / 9 A
63 = 11 A / 9 A
64 = 12 A / 10 A
65 = 15 A / 13 A
66 = 17 A / 17 A
67 = 20 A / 17 A
68 = 22 A / 19 A
69 = 24 A / 21 A
70 = 27 A / 22 A
71 = 30 A / 24 A
72 = 32 A / 27 A
73 = 35 A / 30 A
74 = 44 A / 36 A
75 = 46 A / 39 A
76 = 53 A / 44 A
77 = 54 A / 46 A
78 = 63 A / 53 A
79 = 73 A / 61 A
80 = 80 A / 66 A
81 = 100 A / 85 A
82 = 107 A / 90 A
83 = 108 A / 95 A
84 = 125 A / 107 A
85 = 130 A / 108 A
86 = 150 A / 122 A
87 = 147 A / 127 A
88 = 170 A / 150 A
89 = 195 A / 165 A
90 = 216 A / 180 A
91 = 289 A / 240 A
92 = 259 A / 225 A
93 = 315 A / 289 A
94 = 312 A / 259 A
95 = 365 A / 315 A
96 = 365 A / 312 A
97 = 435 A / 357 A
98 = 428 A / 355 A
99 = 472 A / 388 A
100 = 700 A / 515 A
101 = 1330 A / 979 A
102 = 1995 A / 1468 A
103 = 2660 A / 1957 A
104 = 3325 A / 2446 A
105 = 795 A / 637 A
106 = 877 A / 715 A
107 = 1062 A / 855 A
108 = 1186 A / 943 A
109 = 584 A / 504 A
110 = 478 A / 410 A
111 = 625 A / 540 A
112 = 518 A / 447 A
113 = 758 A / 614 A
114 = 628 A / 518 A
115 = 804 A / 682 A
116 = 703 A / 594 A
117 = 760 A / 600 A
118 = 760 A / 560 A
119 = 226 A / 180 A
P0296
Line Rated Voltage
0 = 200 - 240 V
1 = 380 V
2 = 400 - 415 V
3 = 440 - 460 V
4 = 480 V
5 = 500 - 525 V
6 = 550 - 575 V
7 = 600 V
8 = 660 - 690 V
According to inverter
model
CFG
42
P0297
Switching Frequency
0 = 1.25 kHz
1 = 2.5 kHz
2 = 5.0 kHz
3 = 10.0 kHz
4 = 2.0 kHz
According to inverter
model
CFG
42
P0298
Application
0 = Normal Duty (ND)
1 = Heavy Duty (HD)
0
CFG
42
P0299
DC-Braking Start Time
0.0 to 15.0 s
0.0 s
V/f, VVW
and Sless
47
P0300
DC-Braking Stop Time
0.0 to 15.0 s
0.0 s
V/f, VVW
and Sless
47
Содержание CFW-11 Series
Страница 2: ......
Страница 54: ...2 4 2 General Information ...
Страница 58: ...About the CFW 11 3 3 4 ...
Страница 74: ...Inverter Model and Accessories Identification 5 14 6 ...
Страница 86: ...Inverter Model and Accessories Identification 6 12 6 ...
Страница 94: ...Available Control Types 8 2 8 ...
Страница 118: ...VVW Control 10 8 10 ...
Страница 182: ...Functions Common to All the Control Modes 12 26 12 ...
Страница 220: ...Dynamic Braking 14 4 14 ...