![WEG CFW-11 Series Скачать руководство пользователя страница 242](http://html.mh-extra.com/html/weg/cfw-11-series/cfw-11-series_programming-manual_950630242.webp)
Faults and Alarms
15-22
15
Description:
This parameter indicates, in Celsius degrees, the highest temperature among the PT100 or KTY84 used sensors.
NOTE!
If any of the temperature fault/alarm configuration parameters, P0374, P0377, P0380, P0383
and/or P0386, is programmed with the "Inactive" option, the respective read-only parameter,
P0388, P0389, P0390, P0391 and/or P0392, indicates 0 (zero), not showing the actual sensor
temperature. These inactive sensor inputs do not interfere with the P0393 indication.
When all the read-only parameters indicate 0 (zero), P0393 will also indicate 0 (zero).
The
shows the fault or alarm actuation levels and the level that allows their reset.
Table 15.9 -
Fault and alarm actuation levels
Code
Description
Actuation
Reset
F186
Sensor 1 temperature fault
P0373 = 0: R
PTC
> 1.3 kΩ
P0373 = 1: R
PTC
> 4 kΩ
PT100 and KTY84: P0388 > P0375
P0373 = 0: R
PTC
< 550 Ω
P0373 = 1: R
PTC
< 1.65 kΩ
PT100 and KTY84: P0388 < (P0375 -15 °C)
F187
Sensor 2 temperature fault
P0376 = 0: R
PTC
> 1.3 kΩ
P0376 = 1: R
PTC
> 4 kΩ
PT100 and KTY84: P0389 > P0378
P0376 = 0: R
PTC
< 550 Ω
P0376 = 1: R
PTC
< 1.65 kΩ
PT100 and KTY84: P0389 < (P0378 -15 °C)
F188
Sensor 3 temperature fault
P0379 = 0: R
PTC
> 1.3 kΩ
P0379 = 1: R
PTC
> 4 kΩ
PT100 and KTY84: P0390 > P0381
P0379 = 0: R
PTC
< 550 Ω
P0379 = 1: R
PTC
< 1.65 kΩ
PT100 and KTY84: P0390 < (P0381 -15 °C)
F189
Sensor 4 temperature fault
P0382 = 0: R
PTC
> 1.3 kΩ
P0382 = 1: R
PTC
> 4 kΩ
PT100 and KTY84: P0391 > P0384
P0382 = 0: R
PTC
< 550 Ω
P0382 = 1: R
PTC
< 1.65 kΩ
PT100 and KTY84: P0391 < (P0384 -15 °C)
F190
Sensor 5 temperature fault
P0385 = 0: R
PTC
> 1.3 kΩ
P0385 = 1: R
PTC
> 4 kΩ
PT100 and KTY84: P0392 > P0387
P0385 = 0: R
PTC
< 550 Ω
P0385 = 1: R
PTC
< 1.65 kΩ
PT100 and KTY84: P0392 < (P0387 -15 °C)
A191
Sensor 1 temperature alarm
P0373 = 0: R
PTC
> 1.3 kΩ
P0373 = 1: R
PTC
L > 4 kΩ
PT100 and KTY84: P0388 > (P0375 -10 °C)
P0373 = 0: R
PTC
< 550 Ω
P0373 = 1: R
PTC
< 1.65 kΩ
PT100 and KTY84: P0388 < (P0375 -15 °C)
A192
Sensor 2 temperature alarm
P0376 = 0: R
PTC
> 1.3 kΩ
P0376 = 1: R
PTC
> 4 kΩ
PT100 and KTY84: P0389 > (P0378 -10 °C)
P0376 = 0: R
PTC
< 550 Ω
P0376 = 1: R
PTC
< 1.65 kΩ
PT100 and KTY84: P0389 < (P0378 -15 °C)
A193
Sensor 3 temperature alarm
P0379 = 0: R
PTC
> 1.3 kΩ
P0379 = 1: R
PTC
> 4 kΩ
PT100 and KTY84: P0390 > (P0381 -10 °C)
P0379 = 0: R
PTC
< 550 Ω
P0379 = 1: R
PTC
< 1.65 kΩ
PT100 and KTY84: P0390 < (P0381 -15 °C)
A194
Sensor 4 temperature alarm
P0382 = 0: R
PTC
> 1.3 kΩ
P0382 = 1: R
PTC
> 4 kΩ
PT100 and KTY84: P0391 > (P0384 -10 °C)
P0382 = 0: R
PTC
< 550 Ω
P0382 = 1: R
PTC
< 1.65 kΩ
PT100 and KTY84: P0391 < (P0384 -15 °C)
A195
Sensor 5 temperature alarm
P0385 = 0: R
PTC
> 1.3 kΩ
P0385 = 1: R
PTC
> 4 kΩ
PT100 and KTY84: P0392 > (P0387 -10 °C)
P0385 = 0: R
PTC
< 550 Ω
P0385 = 1: R
PTC
< 1.65 kΩ
PT100 and KTY84: P0392 < (P0387 -15 °C)
A196
Sensor 1 broken cable alarm
P0373 = 0: R
PTC
< 20 Ω
P0373 = 1: R
PTC
< 60 Ω
PT100 and KTY84: P0388 < -20 ºC
P0373 = 0: R
PTC
> 40 Ω
P0373 = 1: R
PTC
> 120 Ω
PT100 and KTY84: P0388 > -20 °C
A197
Sensor 2 broken cable alarm
P0376 = 0: R
PTC
< 20 Ω
P0376 = 1: R
PTC
< 60 Ω
PT100 and KTY84: P0389 < -20 ºC
P0376 = 0: R
PTC
> 40 Ω
P0376 = 1: R
PTC
FIL > 120 Ω
PT100 and KTY84: P0389 > -20 °C
A198
Sensor 3 broken cable alarm
P0379 = 0: R
PTC
< 20 Ω
P0379 = 1: R
PTC
< 60 Ω
PT100 and KTY84: P0390 <-20 ºC
P0379 = 0: R
PTC
> 40 Ω
P0379 = 1: R
PTC
> 120 Ω
PT100 and KTY84: P0390 > -20 °C
A199
Sensor 4 broken cable alarm
P0382 = 0: R
PTC
< 20 Ω
P0382 = 1: R
PTC
< 60 Ω
PT100 and KTY84: P0391 < -20 ºC
P0382 = 0: R
PTC
> 40 Ω
P0382 = 1: R
PTC
> 120 Ω
PT100 and KTY84: P0391 > -20 °C
A200
Sensor 5 broken cable alarm
P0385 = 0: R
PTC
< 20 Ω
P0385 = 1: R
PTC
< 60 Ω
PT100 and KTY84: P0392 < -20 ºC
P0385 = 0: R
PTC
> 40 Ω
P0385 = 1: R
PTC
> 120 Ω
PT100 and KTY84: P0392 >-20 °C
Содержание CFW-11 Series
Страница 2: ......
Страница 54: ...2 4 2 General Information ...
Страница 58: ...About the CFW 11 3 3 4 ...
Страница 74: ...Inverter Model and Accessories Identification 5 14 6 ...
Страница 86: ...Inverter Model and Accessories Identification 6 12 6 ...
Страница 94: ...Available Control Types 8 2 8 ...
Страница 118: ...VVW Control 10 8 10 ...
Страница 182: ...Functions Common to All the Control Modes 12 26 12 ...
Страница 220: ...Dynamic Braking 14 4 14 ...