If a floor drain is not available, a condensate pump can be used to remove the condensate to an
appropriate drain. The maximum condensate flow rate is:
Model
Maximum Condensate Flow Per Unit
CEN2000
16 gallons (38 L) per hour
Figure 2-10: Sample Condensate Trap Installation
2.8 GAS SUPPLY PIPING
W A R N I N G !
Never use matches, candles, flames, or other sources of ignition to check for gas leaks
.
C A U T I O N !
Many of the soaps used for gas pipe leak testing are corrosive to metals. Therefore, piping
must be rinsed thoroughly with clean water after leak checks have been completed
.
NOTE:
All gas piping must be arranged so that it does not inhibit removal of covers or
service/maintenance or restrict access between the unit and walls or other units.
Model
Natural Gas Piping
CEN2000
2 inch (5.08 cm) on top of unit
EXHAUST
MANIFOLD
DRAIN PORT
COMBUSTION
ANALYZER PROBE
PORT
EXHAUST
MANIFOLD
3/4” NPT NIPPLES
HOSE CLAMP
TO
CONDENSATE
NEUTRALIZER
CONDENSATE TRAP
(P/N 24441C)
TOP
COVER
THUMB
SCREWS
(4 each)
1” (2.54 cm) DIAM.
HOSE
4” (10cm)
4-
8” (10
-20
cm) THICK
TRAP INLET
INTEGRAL ADAPTOR AND
THUMBSCREW