Centurion Water Heater- Edge [ii]: Install-Operation-Service
SECTION 7: MAINTENANCE
OMM-0153_A
• 8/25/2022 Technical Support • (800) 526-0288 • Mon-Fri, 8 am - 5 pm EST Page 70 of 131
7.7 CONDENSATE DRAIN TRAP
All CENTURION Water Heaters contain a condensate trap (P/N
24441C
), located external to
the unit, attached to the
exhaust manifold’s drain at the rear of the unit.
This trap must be
inspected
for leaks and blockages,
cleaned
to ensure that the float is free to
move, and condensate flows normally, and the O-Ring (P/N
84017C
included in all 24 Month
Maintenance Kits) replaced if it is worn or damaged. In addition, you must ensure the vent
(under the removable cover) is free and clear of obstructions.
Figure 7-5: External Condensate Trap, Cross-Section & Exploded View
If your system includes a condensate neutralizer, the active ingredient must be periodically
replaced.
Figure 7-6: Condensate Trap and Neutralizer
CONDENSATE TRAP
CONDENSATE
NEUTRALIZER