Jump-starting the engine
WARNING
Explosion hazard in case of incorrect handling of battery!
Can cause serious injury or death.
►
Never jump start the engine if the battery is frozen. Dispose of a frozen
battery.
►
In order to avoid electrical short-circuit or overvoltage, the battery
jumper cable connected on the positive terminals of the batteries must
never be brought into contact with electrically conductive vehicle parts.
►
The vehicles must not touch each other during the starting aid.
►
The voltage of the auxiliary power supply must be 12 V; higher voltage
will damage the electrical system of both vehicles.
►
Use only authorized battery jumper cables which conform to the safety
requirements and which are in perfect condition.
►
Route the battery jumper cables so they cannot catch on rotating
components in the engine compartment.
►
Do not lean over the battery.
►
Keep ignition sources away from the battery.
1. Drive the jump-starting vehicle close enough to the machine so that the
battery jumper cables can reach to connect both batteries.
2. Let the engine of the jump-starting vehicle run.
3. First connect one end of the red battery jumper cable (
+
) to the positive
terminal of the empty battery, then connect the other end to the
positive terminal of the starting battery.
4. Connect one end of the black battery jumper cable (
−
) to the negative
terminal of the starting battery.
5. Connect the other end of the black battery jumper cable (
−
) to a solid
metal component fimly screwed on the engine block or onto the engine
block itself.
➥
Do not connect it to the negative terminal of the empty battery, as
otherwise explosive gas emerging from the battery can ignite if
sparks are formed.
6. Start the engine of the machine with the empty battery.
Once the engine has started:
• With the engine running, disconnect both battery jumper cables in the
reverse order.
Information
In order to avoid sparking, first disconnect the battery jumper cable on the
negative terminal, then the battery jumper cable on the positive terminal.
Fig. 109Overview
Starting
battery
Empty battery
Содержание ET12 02
Страница 8: ...EG 4 BA ET18 20 24 en 1 5 et18_20_24konf fm Declaration of conformity Notes...
Страница 16: ...1 8 BA ET18 20 24 en 1 5 et18_20_24v100 fm 1 Foreword Notes...
Страница 48: ...3 12 BA ET18 20 24 en 1 5 et18_20_24e300 fm 3 Introduction Warning labels Cabin Canopy...
Страница 53: ...BA ET18 20 24 en 1 5 et18_20_24e300 fm 3 17 Introduction 3 Information labels...
Страница 60: ...3 24 BA ET18 20 24 en 1 5 et18_20_24e300 fm 3 Introduction...
Страница 104: ...4 44 BA ET18 20 24 en 1 5 et18_20_24i400 fm 4 Putting into operation...
Страница 118: ...5 14 BA ET18 20 24 en 1 5 et18_20_24b510 fm 5 Operation...
Страница 170: ...5 66 BA ET18 20 24 en 1 5 et18_20_24b510 fm 5 Operation Notes...
Страница 177: ...BA ET18 20 24 en 1 5 et18_20_24t600 fm 6 7 Transport 6 Fig 231Lashing points on either side outside on the travel gear A...
Страница 178: ...6 8 BA ET18 20 24 en 1 5 et18_20_24t600 fm 6 Transport...
Страница 230: ...7 52 BA ET18 20 24 en 1 5 et18_20_24w710 fm 7 Maintenance Notes...
Страница 275: ...BA ET18 20 24 en 1 5 et18_20_24t900 fm 9 43 Technical data 9 Cabin canopy standard travel gear and VDS...
Страница 276: ...9 44 BA ET18 20 24 en 1 5 et18_20_24t900 fm 9 Technical data Dimensions Overview ET18 ET20 ET24...
Страница 280: ...9 48 BA ET18 20 24 en 1 5 et18_20_24t900 fm 9 Technical data Notes...