6-4
BA 5001-6001 US – Edition 1.2 * * 6001b610.fm
Specifications
6.9
Electric system 5001
Fuse box
Relays
The relays are located in the relay box under the the floor panel of the control stand
Electric system
Alternator
12 V 55 A
Starter
12 V 2.6 kW
Battery
12 V 88 Ah
F1
F2
F3
F4
F5
F6
F7
Fig. 92: Fuse box
F8
Fuse
Rated
current (A)
Protected circuit
F 1
10 A
– Instrument panel, fuel supply
F 2
10 A
– Drive solenoid valves
F 3
10 A
– Horn, brake lights
F 4
15 A
– Turn indicators
F 5
15 A
– High beam
F 6
10 A
– Low beam
F 7
15A
– Clearance light
F8
10 A
– Hazard warning system
K 31
K 33
K 32
Fig. 93: Relays
F10
F9
K 10
Switching relay
no.
Protected circuit
F 9, F10
– Main fuses (50 A)
K 31
– Turn indicator relay
K 32
– High beam relay
K 33
– Low beam relay
K 31
– Start relay