C H A P T E R 3 C O N F I G U R I N G V 1 0 0
V100 Versatile Multiplexer Technical Manual Version 2.2
Page 51 of 231
Field Options Description
Auto,
When an alarm event occurs, the
alarm relay is energised after the
programmed delay. It is de-energised
if the alarm condition is removed
(see “Alarms”)
On,
When an alarm event occurs, the
alarm relay is energised after the
programmed delay and stays on
Off,
The alarm relay stays off
ALARM RELAY MODE
Toggle
When an alarm event occurs, the
alarm relay is energised after the
programmed delay and then toggles
on and off according to the delay
period.
UK,
BT standard ringing cadence
US,
AT&T standard ringing cadence
France,
France Telecom standard ringing
cadence
COUNTRY
Germany
Deutsche Telecom ringing cadence
CONNECTION TIMEOUT
10-255 numeric entry
Number of seconds after which a
connection request is rejected
RECEIVE READY FILTER
0-255 numeric entry
Number of seconds from assertion of
RR after which signal is accepted
Auto,
Connection is made when one end is
mapped
DATA CHANNEL
ACTIVATION
Flag
Connection only is made when one
end is mapped AND ‘C’ lead affirmed
at both ends
Always On,
Channel output signal always
asserted
Follows Connect,
Channel output signal asserted when
connection is established
Follows Remote,
Channel output signal follows remote
input signal transparently
DATA CHANNEL FLAG
Follows Alarms
Channel output signal disaffirmed
during alarm conditions
M-Lead
Connections are only made when the
M-Lead is seized.
M-Lead & Back-Busy
Same as above but pings are used to
check the link status. See the section
“TIE LINE ACTIVATION” above this
table for details.
TIE LINE ACTIVATION
Auto
Permanent connection is made which
takes bandwidth all the time.
ASYNC BUFFER SIZE
8-256 numeric entry
Number of 1K buffers used by data
channels in async mode
Master,
Logged unit polls other units on the
HSC bus
HSC MODE
Slave
Logged unit waits to be polled on the
HSC bus and replies
TDM MODE*
RS449, V.35, V.24
Defines the electrical interface
standard of the TDM port.
None,
No Special Option Card fitted
ISDN,
Basic Rate ISDN pump fitted
OPTION 0
E1
E1 Link Card fitted