C H A P T E R 3 C O N F I G U R I N G V 1 0 0
V100 Versatile Multiplexer Technical Manual Version 2.2
Page 112 of 231
Field Options
Description
Dial On Demand,
ISDN number dialled on first bandwidth
request. Incoming calls also answered.
Answer,
Incoming calls answered only.
LINK MODE
Dial Demand/Suspend
ISDN number dialled on first bandwidth
request. Incoming calls also answered. ISDN
connection dropped during idle periods of
async data.
CALL TIMER
5min, 10mins, 20mins,
1 hour, 2 hours, 5
hours,
10 hours, 24 hours,
Permanent
Maximum single call duration. The ISDN call
will be terminated when this duration is
exceeded.
PMP,
Point-to-multipoint. This is the default for Euro
ISDN.
LINE TYPE
PP
Point-to-point. A TEI must be entered in the
range 0-63.
Broadcast 127,
PMP type for information only
TEI
0-63
PP Terminal Endpoint Identifier
EURO ISDN,
ETSI NET3 European protocol. Information
only.
ISDN PROTOCOL
NI (National ISDN),
ATT 5ESS,
Nortel DMS-100
Visible only when the US protocols are loaded.
These are the most common US protocol
types.
Manual,
SPID and LDN must be entered by the user.
Automatic*,
SPID1, LDN1 are displayed automatically
when allocated by the network
SPID ALLOCATION
Auto + SPID
Guessing**
AUTO SPID STATUS
* **Visible only in
Automatic
allocation modes
Displays the current status of SPID
negotiation with the network. The SPID
number is displayed when successful.
SPID1
Special field
Manual : Numeric Entry
Automatic: Information only
Auto+Guessing: 01010101010101
LDN1
Special field
Manual : Numeric Entry
Automatic: Information only
Auto+Guessing: Numeric Entry
SPID2
Special field
Numeric Entry, visible in Manual SPID
allocation
LDN2
Special field
Numeric Entry, visible in Manual SPID
allocation
BoD DIAL THRESH
(bps)
0-64000
Sets the Bandwidth on Demand dial threshold
which determines when the second bearer
channel is dialled.
BoD CLEAR THRESH
(bps)
0-64000
Sets the Bandwidth on Demand clear
threshold which determines when the second
bearer channel is dropped.
BoD DAMPING
FACTOR (%)
0-99
Sets the Bandwidth on Demand damping
factor which is used to calculate traffic levels
and hence whether to dial up or drop the
second bearer channel.
0-86400
Sets the Bandwidth on Demand activity timer
which determines after what time the second
bearer is dropped if the dampened traffic level
remains below the dial threshold
BoD ACTIVITY TIMER
PERMANENT
The second bearer channel is never dropped