C H A P T E R 3 C O N F I G U R I N G V 1 0 0
V100 Versatile Multiplexer Technical Manual Version 2.2
Page 55 of 231
3.4.4
The CLOCKING menu
The clocking menu specifies how the GRX and GTX clocks in the V100 are driven.
NOTE: In earlier versions of software, the reference clock is configured differently. Please refer
to the appropriate manual for more information.
SOURCE
Configures the source for driving the GRX and GTX system clocks.
AGGREGATE
When the SOURCE is configured to DATA, AGGREGATE specifies which data interface clock is driving GRX
or GTX. When SOURCE is configured to IP AGG, AGGREGATE specifies the name of IP Aggregate driving
GRX or GTX. For all other values of SOURCE, the AGGREGATE field is not used.