background image

OPERATING INSTRUCTIONS 

FULL-AUTO DIGITAL ELECTRICAL TESTER

 

PDT35 

 

Safety Information 

 

Never use the tester if it or its test leads appear damaged. 

 

Never apply more than 600V DC or 600V AC rms. Between any terminal 

and earth ground 

  When using the probes, keep your fingers behind the finger guards on 

the probes. 

  Turn off power to the circuit under test before cutting, unsoldering, or 

breaking the circuit. Small amounts of current can be dangerous. 

 

Use caution when working with voltages above 60V DC or 30V AC rms. 

Such voltages pose a shock hazard. 

 

Automatic Operation 

The tester automatically turns on when you short the two test probes or place 

the probes across a complete circuit. 

When turned on, the tester powers up in continuity mode. If a DC or AC 

voltage greater than about 4.0V is present across the inputs, the tester 

switches to DC or AC voltage mode. 

The tester automatically shuts down after approx. 4 minutes of inactivity. 

 

Continuity testing 

Turn off circuit power before testing. 

Beeper indicates shorts lasting 1 ms or longer. 

 
 

 

 

 

   

 

  SHORT         

10K

 

 

        OPEN 

 

 

 

 

 

Measuring Voltage 

Refer to Automatic Selection 

DC Voltage (Volts DC>4.0V) 

 

 

 

AC Voltage (Volts DC>4.0V) 

600V 

DC 

maximum 

     600V 

AC 

maximum 

 

 

 

 

 

 

 

 

 

 

50Hz to 400Hz 

 

 

 

 

 

 

 

 

12V DC                                                            220V AC 

 

 

 

 

 

 

 

 

                                             

 

Specifications 

Function

 

Range 

Accuracy (%rdg. + digits) 

V AC (50Hz~400Hz) 

600V 

+(2.9%+8) 

V DC 

600V 

+(1.5%+2) 

Continuity test: Audible threshold 0~10K

, Continuity beeper 2KHz.

 

Overload protection: AC/DC 600V 

Dimension/wt.: 215x72x36.7mm/235g 

 

Display

: Large 1999 count LCD display with function and high voltage 

warning indication. 

Maximum Voltage Between any Terminal and Earth Ground

:  

600V DC; 600V AC rms, Over-voltage Category III 

Safety

: Complies with EN61010-1:2001 for use in over-voltage CAT III 

environments 

Reviews: