T 5
26
10 ACCESSING THE INTERNAL PARTS - FLARES
Removing the derivative housing
This guard is disassembled by pulling upward, as shown in the figure, moving it first in the direction of the arrow
"
A
", then lifting it off entirely in the direction of the arrow "
B
".
WARNING:
Cut off the electrical power
supply before removing the
housing!
Removing the derivative
housing allows access to parts
that remain live even when the
power switch is turned off!
NOTE:
In the event of a malfunction by the upward chair movement, proceed as follows to free the derivative
housing:
1) Remove the seat upholstery (see the paragraph on "
Removing the seat upholstery
")
2) Loosen the two hexagonal M10 screws "
A
"
3) Turn the mobile part "
C
" in the direction shown by the arrow "
B
"
4) Remove the housing "
D
" by raising it as shown in the figure above, making sure that the chair has first been
disconnected from the electrical power supply
5) Before replacing the seat upholstery, make sure that the two hexagonal M10 screws "
A
" have been firmly
tightened.
A
C
A
B
Connector
block guard
Connector
block guard
B
D