G4 Multi Channel Force Instrument
4-27
Range/Alternatives
Explanation and
<default value>
result of alternatives.
Data Block 1 Type
Not In Use
Sum/Difference
Output 1-2
Output 3-4
Output 5-6
Output 7-8
Input A-B Force
Input C-D Force
Input A-B Signal
Input C-D Signal
Level Status
Input Status
Output Status
Inp./Outp Status
AOUT 1-4 Value
AOUT 1-2 Value
AOUT 3-4 Value
< Not In Use >
Sets the data source for Data Block 1. Selections
Sum/difference, Output 1-2, Output 3-4, Output 5-6, Output 7 -8,
Input A-B Force, Input C-D Force, Input A-B Signal and
Input C-D Signal are values from the selected Function Block,
which is set with parameter Data Block 1 FB. Function block
values are sent together with Error code and Status.
See detailed description of Function Block in chapter 3.
Not In Use: The memory area corresponding to this data block
is not updated.
Sum/Difference: The Sum and Difference values are
transmitted in this Data Block. Floating point or Integer format.
Output 1-2: Output 1 and Output 2 are transmitted in this Data
Block. Floating point or Integer format.
Output 3-4: See description of Output 1-2 above.
Output 5-6: See description of Output 1-2 above.
Output 7-8: See description of Output 1-2 above.
Input A-B Force: Input A Force and Input B Force are
transmitted in this Data Block. Floating point or Integer format.
Input C-D Force: Input C Force and Input D Force are
transmitted in this Data Block. Floating point or Integer format.
Input A-B Signal: Input A Signal and Input B Signal are
transmitted in this Data Block. Floating point or Integer format.
Input C-D Signal: Input C Signal and Input D Signal are
transmitted in this Data Block. Floating point or Integer format.
Level Status: The status of all 32 levels in the instrument is
transmitted in this Data Block. Floating point or Integer format.
Input Status: The status of all inputs in the instrument is
transmitted in this Data Block. Floating-point format.
Output Status: The status of all outputs in the instrument is
transmitted in this Data Block. Floating-point format.
Inp./Outp Status: The status of all inputs and all outputs in the
instrument is transmitted in this Data Block. Integer format.
AOUT1-4 Value: The values of analog outputs 1 to 4 are
transmitted in this Data Block. Floating-point format.
AOUT1-2 Value: The values of analog outputs 1 and 2 are
transmitted in this Data Block. Integer format.
AOUT3-4 Value: The values of analog outputs 3 and 4 are
transmitted in this Data Block. Integer format.
Note: This parameter is only shown if parameter
‘No Of Data Blocks‘ is set to 1 or greater.
Содержание G4-DT
Страница 1: ...G4 Multi Channel Force Instrument Program version 101 1 0 0 Technical Manual PM DT HE types GB ...
Страница 2: ......
Страница 18: ...Technical Manual 1 14 ...
Страница 36: ...Technical Manual 2 18 ...
Страница 45: ...G4 Multi Channel Force Instrument 4 5 ...
Страница 76: ...Technical Manual 4 36 ...
Страница 82: ...Technical Manual 5 6 ...
Страница 92: ...Technical Manual 6 10 ...
Страница 138: ...Technical Manual 7 46 ...
Страница 158: ...Technical Manual 8 20 ...
Страница 164: ...Technical Manual 9 6 ...
Страница 170: ......
Страница 171: ...G4 Multi Channel Force Instrument Appendix 1 ...
Страница 172: ...Technical Manual ...
Страница 173: ......