Technical Manual
3-4
Input A
Sum
Output 3
Input B
Output 4
1 / WTF
Output 7
Output 1
Input C
Output 5
Input D
Output 6
1 / WTF
Output 2
Output 8
Difference
1/2
+
+
+
+
+
+
+
-
WTF = Web Tension Factor
Four Channel Function block, Web Tension mode
Common values
The following table explains the available input values to a Function Block. These
values are the same for a Function Block both in force mode and tension mode.
Value
1 Channel
Func. Block
2 Channel
Func. Block
4 Channel
Func. Block
Input A Force
Inp. A Force
Inp. A Force
Inp. A Force
Input B Force
-
Inp. B Force
Inp. B Force
Input C Force
-
-
Inp. C Force
Input D Force
-
-
Inp. D Force
Input A Signal (mV/V)
Inp. A Signal
Inp. A Signal
Inp. A Signal
Input B Signal (mV/V)
-
Inp. B Signal
Inp. B Signal
Input C Signal (mV/V)
-
-
Inp. C Signal
Input D Signal (mV/V)
-
-
Inp. D Signal