To change the MSGS parameter–
1. Display Setup Menu 2 by pressing [SETUP], then pressing [down arrow] twice.
Setup Menu 2 Error Messages Parameter
2. Move the cursor to MSGS and press [OK] to display the Error Messages parameter.
3. Press [CHG] to cycle between the two choices: 0=do not include the text; 1=include the
text.
4. Press [SETUP] twice to exit setup and return to the EDL.
Troubleshooting
The following are trouble conditions you may encounter and the action to take to prevent or work
around these conditions.
Troubleshooting Table
Trouble
Action
Asterisks (***) display
in the time code field
instead of time code.
Edit Suite is not receiving time code or Real
Time Counter information from the selected
VCR. Verify that the VCR is turned on, the
VCRs counter shows a time value, and all
connections between the VCR and Edit Suite
are secure and correct.
Verify that the PROTO (protocol), VCR
number, TCSRC, and TC Configuration
Parameters are set correctly. Refer to Appendix
A for help in determining these settings. For RS