Edit Suite Version 2.01 (MANL-0588-02)
1
Edit Suite
Version 2.01 Addendum
Edit Suite Version 2.01 adds support for the Videonics MXPro Mixer, provides new VCR Control
Tables and enhances the GPI trigger signal.
If you are already familiar with Edit Suite, the information in this addendum should be all you need to
begin using Version 2.01. If you are new to Edit Suite, glance over the information in the addendum to
see which areas of the product have changed, then use the Edit Suite Instruction Manual to learn how to
use the product. Supplement the information in the manual with the information in this addendum.
Change Summary on this page is a brief listing of the changes for Version 2.01. Change Details, on the
following pages, provide more detailed information about each of the changes.
Change Summary
A. Changes to Support MXPro
1. How to Select
Press Setup, select Config, then select GPI-M. Choices are GPI-M =
MXPRO (default), MX-1 and MIXER. GPI-M = GPI choice removed.
2. NEW tile
"MX1" choice in the NEW tile changed to "MX."
3. MX
tile
- Effect (FX) Number
FX=000-706 (was FX=000-239)
- Tile Type label
shows as MX1 or MXP, depending on GPI-M choice
- Speed
SP=_ (same as previous Edit Suite versions)
- Background Color
C=_ (was BG=_)
- Border Color
B=_ (was BC=_)
- Style (Border Style)
S=_ (added to all MX tiles but only sent if GPI-M = MXPro)
4. Error Message 21
Changed wording: No MX1/MXPRO found.
B. New/Replaced VCR Control Tables
1. Pana_046 and 047
For Panasonic PV-4680, 4690 and 7680
2. Pana_100 (and Lanc_100)
For Panasonic NV-DE3 digital camcorder; for devices that require a
long pause after a Stop command.
3. Lanc_101 (and Pana_101)
If Lanc (or Pana) randomly remains in Play-Pause or Record-Pause
during auto-assemble (auto record).
4. RS232_111, 113, 114 , 115
For RS232 VCRs if RS232_001, 003, 004 or 005, respectively, had
problems when used as a play VCR
5. RS422_009
For RS422, enhances insert editing with 422 VCRs
6. RS422_111, 119
For RS422: May help if auto assemble pauses abnormally.
7. IR Tables
Several IR tables have been replaced.
C. Change to GPI trigger signal
Some third-party devices, such as JVC titlers, would not trigger (play) with previous versions of Edit
Suite. The GPI pulse was modified to support these devices.